Related Experiment Video
Updated: Apr 20, 2026

Treatment of Ankle Osteoarthritis with Total Ankle Replacement Through a Lateral Transfibular Approach
Published on: January 24, 2018
No clinical benefit of high-flex total knee arthroplasty. A meta-analysis of randomized controlled trials
Huichao Fu1, Jiaxing Wang1, Wen Zhang1
1Department of Orthopaedic Surgery, Shanghai Sixth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, People's Republic of China.
Abstract:
The application of high-flex prosthesis in total knee arthroplasty (TKA) is an area of continuing debate. Thus, we conducted a meta-analysis of randomized controlled trials (RCTs). A literature search was performed in PubMed, EMBASE and the Cochrane database. 10 trials involving 1230 knee joints were eligible for our meta-analysis. No significant difference was observed between the two designs regarding postoperative range of flexion, clinical scores, quality of life outcomes, or complication rate. Moreover, the advantage of high-flex implants for patients with high preoperative range remained not statistically significant and high-flex design in NexGen system showed a marginal improvement in the postoperative range of flexion. Based on current findings, high-flex prosthesis did not appear to confer any benefit as compared to standard prosthesis.