Field anesthesia machine ventilator oxygen consumption in models of high and low pulmonary compliance
Dale F Szpisjak1, Cheryl M Starrett-Keller2
1Department of Anesthesiology, Uniformed Services University, Room C-1090, 4301 Jones Bridge Road, Bethesda, MD, 20814.
Abstract:
Field anesthesia machine ventilators powered by compressed gas are designed for remote locations that may lack a pipeline supply of O2. This study determined the O2 consumption of the compPAC ventilator powered by E cylinders when ventilating the Vent Aid Training Test Lung model of high (HC) and low (LC) pulmonary compliance. Consumed O2 was calculated after measuring the mass of O2 depleted from the E cylinder. Three tidal volumes (V(T)) were tested (500, 750, and 1000 mL). The HC and LC settings were 0.100 and 0.020 L/cm H2O, respectively. N = 5 in each group, respiratory rate = 10 bpm, and I:E ratio = 1:2. Data were collected for 20 minutes per run. O2 consumption was directly proportional to V(T) and inversely proportional to compliance. The amount of O2 consumed by the ventilator ranged from 2.19 (interquartile range [IQR] 2.18-2.26) L/min in the HC-500 mL V(T) group to 3.76 (IQR 3.76-3.79) L/min in the HC-1000 mL V(T) group (P = 0.027) and from 2.63 (IQR 2.60-2.66) L/min in the LC-500 V(T) mL group to 4.89 (IQR 4.81-5.05) L/min in the LC-1000 mL V(T) group (P = 0.027). The volume of ventilator drive gas was less than minute ventilation (V(E)) in all groups.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Respiratory Volumes and Capacities I
Mechanical Ventilation I: Indication and Settings
Respiratory Volumes and Capacities
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...