Less invasive surfactant administration is associated with improved pulmonary outcomes in spontaneously breathing
Wolfgang Göpel1, Angela Kribs, Christoph Härtel
1Department of Pediatrics, University of Lübeck, Lübeck, Germany.
Aim:
Providing less invasive surfactant administration (LISA) to spontaneously breathing preterm infants has been reported to reduce mechanical ventilation and bronchopulmonary dysplasia (BPD) in randomised controlled trials. This large cohort study compared these outcome measures between LISA-treated infants and controls.
Methods:
Infants receiving LISA, who were born before 32 gestational weeks and enrolled in the German Neonatal Network, were matched to control infants by gestational age, umbilical cord pH, Apgar-score at 5 min, small for gestational age status, antenatal treatment with steroids, gender and highest supplemental oxygen during the first 12 h of life. Outcome data were compared with chi-square and Mann-Whitney U-tests and adjusted for multiple comparisons.
Results:
Between 2009 and 2012, 1103 infants were treated with LISA at 37 centres. LISA infants had lower rates of mechanical ventilation (41% versus 62%, p < 0.001), postnatal dexamethasone treatment (2.5% versus 7%, p < 0.001), BPD (12% versus 18%, p = 0.001) and BPD or death (14% versus 21%, p < 0.001) than the controls.
Conclusion:
Surfactant treatment of spontaneously breathing infants was associated with lower rates of mechanical ventilation and BPD. Additional large-scale randomised controlled trials are needed to assess the possible long-term benefits of LISA.
More Related Videos
Related Concept Videos
Breathing
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...