Related Experiment Video
Updated: Apr 19, 2026

Atomic Layer Deposition of Vanadium Dioxide and a Temperature-dependent Optical Model
Published on: May 23, 2018
A new sensitive electrochemical method for the determination of vanadium(IV) and vanadium(V) in Benfield sample
Munawar Saeed Qureshi1, Abdull Rahim bin Mohd Yusoff1, Afzal Shah2
1Institute of Environmental & Water Resource Management (IPASA), Universiti Teknologi Malaysia, Skudai, Johor, Malaysia.
Abstract:
Vanadium(IV) and vanadium(V) can be determined by using differential pulse cathodic stripping voltammetry technique (DPCSV). Cupferron (ammonium N-nitrosophenylhydroxylamine) was used as ligand to form complex compounds with vanadium ions in Britton-Robinson buffer (BRB) solution. At concentration lower than 1.0×10(-6) M, both V(IV) and V(V) cupferron complexes showed a single cathodic peak at -0.576 V in BRB of pH 4; thus V(IV) and V(V) ions cannot be differentiated at low concentration. However, the ionic species of vanadium can be differentiated at high concentration in the presence of cupferron. Parameters including pH of BRB solution, initial potential and accumulation potential were optimized. Under the optimized parameters, the limit of detection (LOD) was 0.09 nM, and the peak current was linear in the concentration range 0.01-0.9 µM total vanadium ions. The determination of V(IV) and V(V) ions was carried out at higher concentration in the sample using calibration plot method. At higher concentration range of 10-60 µM V(IV) and V(V) ions were determined with LOD of 1.2 and 1.1 µM, respectively. The developed method was successfully applied to 10,00,000 fold diluted Benfield sample and 0.6227 M total vanadium ions were determined. The determination of V(IV) and V(V) ions were also successfully carried out in artificial sample as well as Benfield sample (dilution factor, 10,000). The concentration of V(IV) and V(V) ions was 22.52 µM and 38.91 µM, respectively, giving total vanadium concentration of 0.6143 M in Benfield sample.
Related Concept Videos
Voltammetry: Stripping Methods
Anodic Stripping Voltammetry (ASV)
ASV is used to determine metals and metalloids at trace levels. It involves two steps: deposition and stripping. First, a negative potential is applied to the...
Voltammetry: Overview
A voltammetric cell uses three electrodes: a working electrode, a reference electrode, and an auxiliary electrode. The redox reactions occur in the working...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Voltammetric Techniques: Pulse Voltammetry
Voltammetric Techniques: Linear-Scan (E vs Time)