Related Experiment Video
Updated: Apr 19, 2026

Development and Validation of Chromium Getters for Solid Oxide Fuel Cell Power Systems
Published on: May 26, 2019
Long-term effect of low concentration Cr(VI) on P removal in granule-based enhanced biological phosphorus removal
Jing Fang1, Bin Su1, Peide Sun2
1School of Environmental Science and Engineering, Zhejiang Gongshang University, Hangzhou 310012, China.
Abstract:
In light of the fact that most wastewater in China contained both industrial and domestic wastewater, a 52-d systematical investigation was conducted on the long-term effect of low concentration Cr(VI) (0.3-0.8 mg L(-1)) on P removal performance of granule-based EBPR system in this study. The mechanisms were likewise discussed. Results showed that high Cr(VI) concentration (⩾0.5 mg L(-1)) could significantly inhibit P removal, while this phenomenon was not found when Cr(VI) concentration was less than (or equal to) 0.4 mg L(-1). Most of the granules was disintegrated and filamentous bacteria overgrew inducing sludge bulking occurred at 0.7 mg L(-1) Cr(VI). During the exposure test, the abundance of poly-phosphate-accumulating organisms (PAOs) significantly decreased while the populations of glycogen accumulating organisms (GAOs) and other bacteria increased. Both production and degradation of poly-β-hydroxyakanoates (PHAs) were apparently inhibited. An improved polysaccharide/protein (PS/PN) ratio was observed with the increasing Cr(VI) concentration, implying excessive polysaccharide was secreted by microorganisms to support its resistance to the toxicity of Cr(VI). Besides, good linear regression between PS/PN ratio and the granule size (R(2)=-0.86, p<0.01) was obtained, indicating that high PS/PN was adverse to granule stability. Correlation analysis indicated that the accumulation of granules intracellular Cr was directly responsible for the observed inhibitory effect on P removal process. The long-term Cr(VI) treatment had irreversible effects on granule-based EBPR system as it could not revive after a 16-d recovery process.
More Related Videos
08:21Optimized Procedure for Determining the Adsorption of Phosphonates onto Granular Ferric Hydroxide using a Miniaturized Phosphorus Determination Method
Published on: May 18, 2018
09:23Removal of Trace Elements by Cupric Oxide Nanoparticles from Uranium In Situ Recovery Bleed Water and Its Effect on Cell Viability
Published on: June 21, 2015
Related Concept Videos
Microbial Bioremediation of Uranium
Factors Affecting Solubility
The Phosphorus Cycle
Extraction: Advanced Methods