1Eaton-Peabody Laboratories, Massachusetts Eye and Ear Infirmary, 243 Charles Street, Boston, Massachusetts 02114.
The Journal of the Acoustical Society of America
|December 7, 2014
Summary
The method of lumens for acoustic reflectance calculation has flaws. Even reformulated versions fail to accurately predict reflectance at duct constrictions, violating energy conservation principles.
Area of Science:
- Acoustics
- Wave propagation
- Computational physics
Background:
- The method of lumens was developed to compute plane-wave reflectance in ducts with nonuniform impedance.
- This method involves segmenting the duct into subducts (lumens) and combining individual reflectance solutions.
- It offers intuitive appeal and ease of time-domain implementation.
Purpose of the Study:
- To evaluate the accuracy of the method of lumens for a well-defined acoustic problem.
- To test the method's performance in calculating reflectance at an area constriction in a lossless duct.
- To identify and explain the limitations and errors of the method of lumens.
Main Methods:
- Application of the method of lumens to an area constriction in an infinite lossless duct in the long-wavelength limit.
- Analysis of both the original and a reformulated version of the method of lumens.
- Comparison of computed reflectance with known analytical solutions for the textbook problem.
Main Results:
- The original method of lumens violates energy conservation unless the termination impedance is uniform.
- Neither the original nor the reformulated method of lumens provides the correct reflectance solution for an area constriction.
- The study elucidates the nature of the errors inherent in the method of lumens.
Conclusions:
- The method of lumens, despite its intuitive appeal, is not universally applicable for accurate acoustic reflectance computation.
- The method's limitations, particularly concerning energy conservation and accuracy in nonuniform impedance scenarios, are significant.
- Further research is needed to address the fundamental issues identified in the method of lumens.
Related Concept Videos
Photoluminescence: Applications
1.3K
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
1.3K
Photoluminescence: Fluorescence and Phosphorescence
6.7K
Photoluminescence is a process where a molecule absorbs light energy and re-emits it in the form of light. This phenomenon occurs when a substance absorbs photons, promoting its electrons to higher energy level excited states, followed by a relaxation process in which the electrons return to their original ground state energy levels and emit light. Photoluminescence is widely observed in various materials, including semiconductors, and organic and inorganic compounds.
A pair of electrons in a...
A pair of electrons in a...
6.7K
Fluorescence and Phosphorescence: Instrumentation
2.1K
Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
2.1K