Related Experiment Video
Updated: Apr 19, 2026

Continuous Venous-Arterial Doppler Ultrasound During a Preload Challenge
Published on: January 20, 2023
Oesophageal Doppler cardiac output monitoring: a longstanding tool with evolving indications and applications
Douglas A Colquhoun1, Anthony M Roche2
1Department of Anesthesiology, University of Virginia Health Sciences Center, Charlottesville, VA, USA.
Abstract:
Much work has been done over the years to assess cardiac output and better grasp haemodynamic profiles of patients in critical care and during major surgery. Pulmonary artery catheterization has long been considered as the standard of care, especially in critical care environments, however this dogma has been challenged over the last 10-15 years. This has led to a greater focus on alternate, lesser invasive technologies. This review focuses on the scientific and clinical outcomes basis of oesophageal Doppler monitoring. The science underpinning Doppler shift assessment of velocity stretches back over 100 years, whereas the clinical applicability, and specifically clinical outcomes improvement can be attributed to the last 20 years. Oesophageal Doppler monitoring (ODM), and its associated protocol-guided fluid administration, has been shown to reduce complications, length of stay, and overall healthcare cost when incorporated into perioperative fluid management algorithms. However, more recent advances in enhanced recovery after surgery programs have led to similar improvements, leading the clinician to consider the role of Oesophageal Doppler Monitor to be more focused in high-risk surgery and/or the high-risk patient.
More Related Videos
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
06:10Author Spotlight: Assessment of Cardiac Output Calculation by Thermodilution in Pigs for Effective Perfusion Flow During EVLP
Published on: June 28, 2024
Related Concept Videos
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...