Invasive Hemodynamic Monitoring of Aortic and Pulmonary Artery Hemodynamics in a Large Animal Model of ARDS
Published on: November 26, 2018
Impact of hemodynamic monitoring on clinical outcomes
Emily A Downs1, James M Isbell1
1Division of Thoracic and Cardiovascular Surgery, Department of Surgery, University of Virginia, Charlottesville, VA 22908, USA.
Abstract:
In recent years, there has been a tremendous growth in available hemodynamic monitoring devices to support clinical decision-making in the operating room and intensive care unit. In addition to the "tried and true" heart rate and blood pressure monitors, there are several newer applications of existing technologies including arterial waveform analysis, intraoperative and bedside critical care echocardiography, esophageal Doppler, and tissue oximetry, among others. Several monitoring devices demonstrate positive effect on outcomes, especially when used in conjunction with specific goal-directed therapy protocols to achieve a desired clinical effect. Other devices remain in the validation stage, awaiting comprehensive comparison to established techniques. While these new technologies offer promising advances in intraoperative and critical care, they are often quite costly and many devices lack strong evidence for widespread adoption into clinical practice. In this review, we highlight the current data on clinical outcomes with the use of available hemodynamic monitoring devices.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Errors occurring during blood pressure monitoring
Several factors...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Cardiomyopathy VII: Pre and Post Operative Nursing Management
Holter Monitor: 24-Hour Monitoring