Exploring the speed-resolution limits of supercritical fluid chromatography at ultra-high pressures
Ruben De Pauw1, Konstantin Shoykhet Choikhet2, Gert Desmet1
1Vrije Universiteit Brussel, Department of Chemical Engineering (CHIS-IR), Pleinlaan 2, 1050 Brussels, Belgium.
Abstract:
The limits of supercritical fluid chromatography have been experimentally explored using inlet pressures at the limits of the current commercial instrumentation (400-600 bar), as well as pressures significantly surpassing this (up to 1050 bar). It was found that efficiencies in the range of 200,000 theoretical plates can be achieved for a void time t0 of roughly 6min using superficially porous particles (2.7 and 4.6μm) while remaining within the pressure limits of current commercial instrumentation and columns. If lower efficiencies are sufficient (<100, 000 plates), smaller particles (e.g. 1.8μm) provide the best trade-off between analysis time and efficiency. Apparent efficiencies of 83,000 (k'=2.2) to 76,000 (k'=6.6) plates could be achieved for void times around 1min by pushing the pressure limits up to 1050 bar on a column length of 500mm. As the optimal mobile phase velocity for these small particle columns is even higher, it is required to use narrow-bore columns (2.1mm ID) to remain within the instrument limits of flow rate. The smaller column volume however puts a strain on the separation efficiency due to extra-column band broadening, resulting in losses up to 50% for weakly retained compounds for column lengths below 250mm. It is also illustrated that when using sub-2μm particles, especially for separations where a significant amount of organic modifier is required, the current pressure limits of state-of-the-art instrumentation can sometimes be insufficient. For a gradient running from 4 to 40 v% methanol on a 300mm column at the optimal flow rate the pressure increases from 420 to 810 bar. Operating SFC-columns with a large pressure gradient induces several (undesired) side effects which have been investigated as well. It has been found that, since the viscosity increases strongly with pressure in SFC, the optimal flow rate and the minimal plate height can significantly change when the column length is changed. Whereas e.g. a 3×150mm column (2.7μm particles) has an optimal flow rate of 1.5ml/min and minimal plate height of 5.66μm, a 3×1050mm column has an optimal flow rate of 1.2ml/min and a minimal plate height of 6.25μm. Nevertheless, an increase in operating pressure drop in SFC results in a significant gain in kinetic performance.
More Related Videos
08:42High-Sensitivity Nuclear Magnetic Resonance at Giga-Pascal Pressures: A New Tool for Probing Electronic and Chemical Properties of Condensed Matter under Extreme Conditions
Published on: October 10, 2014
07:26Improving High Viscosity Extrusion of Microcrystals for Time-resolved Serial Femtosecond Crystallography at X-ray Lasers
Published on: February 28, 2019
Related Concept Videos
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
High-Performance Liquid Chromatography: Instrumentation
High-Performance Liquid Chromatography: Elution Process
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...