What experimental factors influence the accuracy of retention projections in gas chromatography-mass spectrometry?
Michael B Wilson1, Brian B Barnes2, Paul G Boswell1
1Department of Horticultural Science, University of Minnesota, 1970 Folwell Avenue, St. Paul, MN 55108, USA.
Abstract:
Programmed-temperature gas chromatographic (GC) retention information is difficult to share because it depends on so many experimental factors that vary among laboratories. Though linear retention indexing cannot properly account for experimental differences, retention times can be accurately calculated, or "projected", from shared isothermal retention vs. temperature (T) relationships, but only if the temperature program and hold-up time vs. T profile produced by a GC is known with great precision. The effort required to measure these profiles were previously impractical, but we recently showed that they can be easily back-calculated from the programmed-temperature retention times of a set of 25 n-alkanes using open-source software at www.retentionprediction.org/gc. In a multi-lab study, the approach was shown to account for both intentional and unintentional differences in the temperature programs, flow rates, and inlet pressures produced by the GCs. Here, we tested 16 other experimental factors and found that only 5 could reduce accuracy in retention projections: injection history, exposure to very high levels of oxygen at high temperature, a very low transfer line temperature, an overloaded column, and a very short column (≤15m). We find that the retention projection methodology acts as a hybrid of conventional retention projection and retention indexing, drawing on the advantages of both; it properly accounts for a wide range of experimental conditions while accommodating the effects of experimental factors not properly taken into account in the calculations. Finally, we developed a four-step protocol to efficiently troubleshoot a GC system after it is found to be yielding inaccurate retention projections.
More Related Videos
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Chromatographic Methods: Terminology
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...