Related Experiment Video
Updated: Apr 19, 2026

Adaptation of Microelectrode Array Technology for the Study of Anesthesia-induced Neurotoxicity in the Intact Piglet Brain
Published on: May 12, 2018
Direct measurement of time-dependent anesthetized in vivo human pulp temperature
Patrício Runnacles1, Cesar Augusto Galvão Arrais1, Marcia Thais Pochapski1
1Department of Restorative Dentistry, State University of Ponta Grossa, Rua General Carlos Cavalcanti, 4748, Uvaranas, Ponta Grossa 84030-900, PR, Brazil.
Objectives:
Human intrapupal tooth temperature is considered to be similar to that of the body (≈37 °C), although the actual temperature has never been measured. This study evaluated the in vivo, human, basal, coronal intrapulpal temperature of anesthetized upper first premolars.
Methods:
After approval of the local Ethics Committee was obtained (protocol no. 255,945), upper right and left first premolars requiring extraction for orthodontic reasons from 8 volunteers, ranging from 12 to 30 years old, received infiltrative and intraligamental anesthesia. The teeth (n=15) were isolated using rubber dam and a small, occlusal preparation was made using high-speed handpiece, under constant air-water spray, until a minute pulp exposure was attained. The sterile probe from a wireless, NIST-traceable, temperature acquisition system (Thermes WFI) was inserted directly into the coronal pulp. Once the probe was properly positioned and stable, real-time temperature data were continuously acquired for approximately 25 min. Data (°C) were subjected to 2-tailed, paired t-test (α=0.05), and the 95% confidence intervals for the initial and 25-min mean temperatures were also determined.
Results:
The initial pulp temperature value (31.8±1.5 °C) was significantly lower than after 25-min (35.3±0.7 °C) (p<0.05). The 95% confidence interval for the initial temperature ranged from 31.0 to 32.6 °C and from 35.0 to 35.7 °C after 25 min. A slow, gradual temperature increase was observed after probe insertion until the pulp temperature reached a plateau, usually after 15 min.
Significance:
Consistent coronal, human, in vivo temperature values were observed and were slightly, but significantly below that of body core temperature.
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...

