Thermally sensitive behavior explanation for unusual orthogonality observed in comprehensive two-dimensional gas
Yada Nolvachai1, Chadin Kulsing, Philip J Marriott
1Australian Centre for Research on Separation Science, School of Chemistry, Monash University , Wellington Road, Clayton, Victoria 3800, Australia.
Abstract:
In this study, a theoretical concept and method to achieve a degree of orthogonality in comprehensive two-dimensional gas chromatography (GC × GC) for separation of fatty acid methyl esters (FAME) by using a single ionic liquid (IL) stationary phase (1-phase-GC × GC) were established. The 1-phase system comprises a long IL column and shorter IL column of the same phase before and after the modulation region, operated under temperature-programmed conditions. Initial isothermal experiments employing six commercial IL columns were conducted at different temperatures. On the basis of the temperature-dependent linear solvation energy relationship (LSER) concept, SLB-IL111 exhibited the greatest thermal sensitivity and degree of difference over the tested temperature (T) range, so it was selected for investigation of the 1-phase-GC × GC mode. With the same temperature program, a significantly high degree of orthogonality was observed for the experiment, varied with column lengths. The switchable separation result, which inverts the retention of saturated and unsaturated FAME on the downstream column ((2)D), was achieved by varying column diameters and surface thicknesses of the IL-coated layers. These results were explained according to the corresponding LSER principles. Also, the time summation model was applied for the simulation of the observed 1-phase-GC × GC results.
More Related Videos
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...