Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Interfacial Electrochemical Methods: Overview01:06

Interfacial Electrochemical Methods: Overview

1.1K
Interfacial electrochemical methods focus on the phenomena occurring at the boundary between an electrode and a solution, as opposed to bulk methods that concentrate on the solution's overall properties. These interfacial methods are classified as either static or dynamic based on the presence of a nonzero current in the electrochemical cell and the consistency of analyte concentrations. Static methods, such as potentiometry, measure the cell's potential without any significant current...
1.1K
Electrogravimetric Analysis: Overview01:30

Electrogravimetric Analysis: Overview

977
Electrogravimetric analysis measures the weight of an analyte deposited electrolytically onto a suitable working electrode. This method involves applying a potential to a pre-weighed electrode submerged in a solution, which results in the desired substance being deposited through reduction at the cathode or oxidation at the anode. The electrode's weight is recorded after deposition, and the difference in weight gives the analyte's weight in the solution.
To test the completeness of the...
977
Voltammetric Techniques: Linear-Scan (E vs Time)01:12

Voltammetric Techniques: Linear-Scan (E vs Time)

2.2K
Polarography is a classical voltammetric technique used to analyze electrochemical reactions. This method applies a linear potential sweep to a dropping mercury electrode (DME), and the resulting current is measured. A dropping mercury electrode is commonly used as the working electrode in polarography. It consists of a capillary tube filled with mercury, where the tiny droplet forms at the tip. This droplet continuously drops from the capillary, creating a new electrode surface for each...
2.2K
Controlled-Potential Coulometry: Electrolytic Methods01:17

Controlled-Potential Coulometry: Electrolytic Methods

897
Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential...
897
Controlled-Current Coulometry: Overview01:27

Controlled-Current Coulometry: Overview

887
Controlled current coulometry, also known as amperostatic coulometry, is a technique used in electrochemical analysis to measure the quantity of a substance through the controlled passage of current. It involves the application of a constant current to an electrochemical cell containing the analyte of interest. As the current flows through the cell, the analyte undergoes a redox reaction at the electrode surface, resulting in a charge transfer. By monitoring the time required for a certain...
887
Electrodes: Overview01:17

Electrodes: Overview

3.2K
 Electrochemical measurements are conducted in an electrochemical cell composed of various components that control and measure the current and potential. One fundamental component is electrodes, conductive materials that enable electron transfer reactions at their surfaces.
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
3.2K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

RoseVisuals: A Multi-Class Dutch Rose Petal Images Dataset for Automated Health and Pigmentation Classification via Deep Learning.

Scientific data·2026
Same author

AND-logic MRI contrast by water flux modulation.

Chemical science·2026
Same author

Slowing Down Water: Enhanced and Cation-responsive MRI Contrast.

Angewandte Chemie (International ed. in English)·2026
Same author

Widespread omission of aptamer-target binding verification in aptasensor development: Consequences for sensor performance and the need for a K<sub>d</sub> gate.

Biosensors & bioelectronics·2026
Same author

Halogen bonding and hydrogen bonding fluorescent anion sensing at the solid-liquid interface.

Chemical science·2026
Same author

Circulating tumour cells as a window into lethality in prostate cancer.

Nature reviews. Urology·2026
Same journal

Machine Learning-Assisted Label-Free SERS Decoding of Mitochondrial Molecular Dynamics in Ovarian Granulosa Cells during Aging.

Analytical chemistry·2026
Same journal

Revealing the Regulatory Interplay of NHE1 mRNA and Na<sup>+</sup> in Cancer Cells Using a DNA Nanosensor.

Analytical chemistry·2026
Same journal

Towards Cellular Resolution of Tryptic Peptides in Tissue Sections by MALDI MS Imaging: A Focus on Enzyme Application and Reproducibility.

Analytical chemistry·2026
Same journal

Bioinspired Bilayer Hydrogel Colorimetric Sensor Array for Low-Temperature Food Freshness Analysis.

Analytical chemistry·2026
Same journal

Quartz Crystal Microbalance-Based Point-of-Care Testing Systems: Principles, Device Design, and Applications.

Analytical chemistry·2026
Same journal

Heterojunction Gate-Empowered OPECT Aptasensing: A Valid Protocol for Realizing High Current Gain at Low Electron Donor Dependency.

Analytical chemistry·2026
See all related articles

Related Experiment Video

Updated: Apr 19, 2026

Electrochemical Impedance Spectroscopy as a Tool for Electrochemical Rate Constant Estimation
08:41

Electrochemical Impedance Spectroscopy as a Tool for Electrochemical Rate Constant Estimation

Published on: October 10, 2018

26.1K

Immittance electroanalysis in diagnostics.

Amol V Patil1, Flávio C Bedatty Fernandes, Paulo R Bueno

  • 1Department of Chemistry, University of Oxford , South Parks Road, Oxford OX1 3QZ, United Kingdom.

Analytical Chemistry
|December 10, 2014
PubMed
Summary
This summary is machine-generated.

This study introduces new electroanalytical assay methods using immittance functions for faster, more sensitive detection of interfacial changes. These advanced techniques improve assay performance without needing equivalent circuit analysis.

More Related Videos

In Situ Lithiated Reference Electrode: Four Electrode Design for In-operando Impedance Spectroscopy
09:36

In Situ Lithiated Reference Electrode: Four Electrode Design for In-operando Impedance Spectroscopy

Published on: September 12, 2018

9.3K
Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis
07:17

Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis

Published on: August 17, 2022

3.7K

Related Experiment Videos

Last Updated: Apr 19, 2026

Electrochemical Impedance Spectroscopy as a Tool for Electrochemical Rate Constant Estimation
08:41

Electrochemical Impedance Spectroscopy as a Tool for Electrochemical Rate Constant Estimation

Published on: October 10, 2018

26.1K
In Situ Lithiated Reference Electrode: Four Electrode Design for In-operando Impedance Spectroscopy
09:36

In Situ Lithiated Reference Electrode: Four Electrode Design for In-operando Impedance Spectroscopy

Published on: September 12, 2018

9.3K
Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis
07:17

Evaluation of Fluid Overload by Bioelectrical Impedance Vectorial Analysis

Published on: August 17, 2022

3.7K

Area of Science:

  • Electrochemistry
  • Analytical Chemistry
  • Spectroscopy

Background:

  • Impedance electroanalytical assays offer high sensitivity for detecting interfacial changes, like molecular binding.
  • Traditional impedance analyses can be time-consuming and may require specific assumptions about the system.

Purpose of the Study:

  • To introduce novel, mathematically derived immittance functions for electroanalytical assays.
  • To enhance assay sensitivity and reduce assay times compared to conventional impedance methods.
  • To provide a method that optimizes analytical potency and frequency selection.

Main Methods:

  • Utilized a portfolio of mathematically derived immittance functions from raw impedance data.
  • Applied the methodology to both faradaic (redox probe amplified) and non-faradaic assays.
  • Focused on optimizing analytical potency and frequency selection without requiring equivalent circuit analysis.

Main Results:

  • Achieved increased assay sensitivity from the same raw data sets.
  • Demonstrated markedly shorter assay times compared to traditional impedance analyses.
  • Enabled selection of frequency-optimized reporters for interfacial changes.

Conclusions:

  • The developed immittance functions offer a powerful approach to enhance electroanalytical assay performance.
  • This method provides a faster and more sensitive alternative to traditional impedance techniques.
  • Optimized frequency selection allows for rapid, single-frequency analyses.