Related Experiment Video
Updated: Apr 19, 2026

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
Published on: February 19, 2021
Assessing the spatial precision of SE and GE-BOLD contrast at 7 Tesla
Rosa M Sanchez Panchuelo1, Denis Schluppeck, Jack Harmer
1Sir Peter Mansfield Magnetic Resonance Centre, School of Physics and Astronomy, University Park, University of Nottingham, Nottingham, NG7 2RD, UK, rosa.panchuelo@nottingham.ac.uk.
Abstract:
Spin echo (SE) EPI offers an alternative to standard gradient echo (GE) EPI for functional MRI. SE-EPI offers improved spatial specificity, since signal changes originate from the microvasculature, but its lower functional sensitivity has limited the usage of this sequence in fMRI experiments. Differential fMRI paradigms, in which two closely matched stimulus conditions are used, can suppress the contribution from veins, thus also offering improved spatial specificity compared to conventional block or event-related designs with long "rest" periods. In this study, we employed a differential fMRI paradigm to stimulate bands of primary visual cortex with pre-defined widths by using visual stimuli comprised of complementary rings of contrast-reversing checkerboard patterns (8 Hz). This paradigm was used to investigate the spatial specificity of GE and SE-BOLD contrast at 7T. Results show that the contrast-to-noise ratio (CNR) is larger for GE-EPI data than for the SE-EPI data for band widths in the range 1.7-6.6 mm, however as the width of the band decreases the CNR for GE and SE sequences converges. These results suggest that when using a differential mapping paradigm, GE-BOLD contrast is better for studying functional features that are larger than ~1.5 mm in size.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Magnetic Resonance Imaging
NMR Spectrometers: Resolution and Error Correction
Magnetic Susceptibility and Permeability
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...

