Retinal nerve fibre layer thickness floor and corresponding functional loss in glaucoma
Jean-Claude Mwanza1, Donald L Budenz1, Joshua L Warren2
1Department of Ophthalmology, University of North Carolina, Chapel Hill, North Carolina, USA.
The British Journal of Ophthalmology
|December 11, 2014
Summary
Glaucoma research shows that retinal nerve fibre layer (RNFL) thickness measurements reach a floor at different visual field (VF) loss levels depending on the device used. Nasal and temporal RNFL are thinner than superior and inferior RNFL.
Area of Science:
- Ophthalmology
- Medical Imaging
- Glaucoma Research
Background:
- Glaucoma is a leading cause of irreversible blindness.
- Retinal nerve fibre layer (RNFL) thickness is a key indicator in glaucoma diagnosis and monitoring.
- Understanding the limits of RNFL measurement is crucial for accurate glaucoma assessment.
Purpose of the Study:
- To determine the minimum measurable retinal nerve fibre layer (RNFL) thickness in glaucoma patients.
- To correlate RNFL thickness floor with corresponding visual field (VF) sensitivity loss.
- To compare RNFL measurement floors between Spectralis and RTVue devices.
Main Methods:
- Review of visual field (VF), Spectralis RNFL, and RTVue RNFL data from glaucoma patients and healthy subjects.
- Application of two Bayesian change point models to estimate global and quadrant residual RNFL thicknesses.
- Correlation of estimated RNFL thicknesses with corresponding VF losses.
Main Results:
- RNFL thinning reached a measurement floor at different visual field loss levels for Spectralis and RTVue devices.
- Nasal and temporal RNFL quadrants consistently showed thinner residual layers compared to superior and inferior quadrants.
- No significant differences were found in post-change point residual RNFL thicknesses between the two models used.
Conclusions:
- The Spectralis device indicated a lower visual field loss threshold for RNFL thinning floor compared to RTVue.
- RNFL measurements below determined minimums provide limited clinical value.
- Findings highlight the importance of device-specific interpretation of RNFL thickness in glaucoma management.
Related Concept Videos
Anatomy of the Eyeball
12.2K
The eye is a spherical, hollow structure composed of three tissue layers. The outer layer — the fibrous tunic, comprises the sclera — a white structure — and the cornea, which is transparent. The sclera encompasses some of the ocular surface, most of which is not visible. However, the 'white of the eye' is distinctively visible in humans compared to other species. The cornea, a clear covering at the front of the eye, enables light penetration. The eye's middle...
12.2K
Diabetic Retinopathy
11
DefinitionDiabetic retinopathy is a microvascular complication of diabetes affecting the retinal blood vessels.Risk FactorsDiabetic retinopathy is present in almost all individuals with type 1 diabetes and more than 60% of those with type 2 diabetes after two decades of disease.The risk increases with poor glycemic control, hypertension, dyslipidemia, smoking, pregnancy, and puberty.Although cataracts and glaucoma are also more frequent in people with diabetes, retinopathy remains the leading...
11
Glaucoma: Overview
1.7K
Glaucoma is an eye condition characterized by increased intraocular pressure that damages the retina and optic nerve, leading to irreversible blindness if left untreated. The human eye has various components, including the cornea, iris, pupil, lens, and optic nerve. Aqueous humor is secreted by the epithelium of the ciliary body in the posterior chamber and flows through the trabecular meshwork and canal of Schlemm, maintaining normal intraocular pressure. The trabecular meshwork and the canal...
1.7K