Related Experiment Video
Updated: Apr 19, 2026

Expired CO2 Measurement in Intubated or Spontaneously Breathing Patients from the Emergency Department
Published on: January 29, 2011
Quantitative or qualitative carbon dioxide monitoring for manual ventilation: a mannequin study
G A Hawkes1, M Kenosi, C A Ryan
1Department of Paediatrics and Child Health, University College Cork, Ireland; Irish Centre for Fetal and Neonatal Translational Research (INFANT), Cork, Ireland.
Aim:
To compare the effectiveness of an in-line EtCO2 detector (DET) and a quantitative EtCO2 detector (CAP), both attached to a t-piece resuscitator, during PPV via a face mask.
Methods:
Paediatric trainees were randomly assigned to determine the method of PPV they commenced with (No device (ND), DET or CAP). Participants used each method for 2 min. Participants were video-recorded to determine the amount of effective ventilations delivered with each method.
Results:
Twenty-three paediatric trainees provided a total of 6035 ventilations, and 91.2% were deemed effective. The percentages of median effective ventilations with the ND, the DET and the CAP were 91.0%, 93.0% and 94.0%, respectively. Fourteen (61%) of the trainees indicated a preference for the DET method, 8 (35%) for the CAP method, and 1 (4%) of the trainees indicated a preference for the ND method. Capnography was the most effective method per patient.
Conclusion:
There was no adverse effect with the addition of EtCO2 detectors. Trainees favoured methods of EtCO2 monitoring during ventilation. The NeoStat device was the preferred device by the majority. The greatest efficacy was achieved with the capnography device. Capnography may enhance face mask ventilation.
More Related Videos
07:51Evaluation of Capnography Sampling Line Compatibility and Accuracy when Used with a Portable Capnography Monitor
Published on: September 29, 2020
08:25Combining Volumetric Capnography And Barometric Plethysmography To Measure The Lung Structure-function Relationship
Published on: January 8, 2019
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Assessment of Ventilation I: Respiratory Rate
A Ventilation assessment is critical for monitoring a patient's health status. Respiration, one of the most accessible vital signs, provides insights into the function of numerous body systems and can indicate serious health issues, such as brainstem injuries from head trauma.
Critical Guidelines for Assessing Ventilation:
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like...