Related Experiment Videos
In vivo ESR dosimetry in total body irradiation
P L Indovina1, M Benassi, G C Giacco
1Dipartimento di Scienze Fisiche, Università di Napoli.
Abstract:
Total body irradiation (TBI) using high doses (about 10 Gy) with photons in the range between 1 and 10 MV combined with intensive chemotherapy has been used successfully in treatment of acute and chronic leukemia before bone marrow transplantation. One of the principal international guidelines in TBI is to use in vivo dosimetry in order to compare the prescribed dose with that absorbed. The use of in vivo dosimetry is also useful as a retrospective evaluation of any deviation from the prescribed dose greater than +/- 5% for relevant parts of the body, especially in the lung and in other organs at risk. In this paper, Electron Spin Resonance (ESR), using alanine dosimeters, is demonstrated to be a powerful tool for absorbed dose evaluation in TBI by detection of free radicals produced in alanine by ionizing radiation. In this study, we present the results obtained using ESR dosimetry in eleven patients undergoing TBI. The major advantages appear to be: 1. the ESR signal in alanine dosimetry is stable for years without fading: 2. the detection of the ESR signal does not destroy the information and so enables a retrospective judgment of the TBI plan adopted.