Related Experiment Video
Updated: Apr 19, 2026

Author Spotlight: Advancing Syphilis Research — Innovations in Treponema pallidum Cultivation and Genetic Engineering
Published on: January 24, 2025
Point-of-care treponemal tests for neurosyphilis diagnosis
Emily L Ho1, Lauren C Tantalo, Trudy Jones
1From the Department of Neurology, University of Washington, Seattle, WA.
Background:
The laboratory diagnosis of neurosyphilis rests upon identifying cerebrospinal fluid (CSF) abnormalities, including CSF-Venereal Disease Research Laboratory (VDRL) reactivity. The CSF-VDRL may not be available in the parts of the world where neurosyphilis is most common. Treponemal immunochromatographic strip tests (ICSTs) have been developed as point-of-care tests on blood for syphilis diagnosis in resource-limited settings.
Methods:
We optimized 3 commercial ICSTs for performance on CSF and tested CSF samples from 217 patients with syphilis. The Syphicheck-WB test (Qualpro Diagnostics, Goa, India; "Syphicheck") was chosen for further study based on agreement with CSF-VDRL test results. We determined CSF-Syphicheck titers for 152 samples. We modified the CSF-Syphicheck for point-of-care testing in a US sexually transmitted diseases clinic and compared results on 102 paired centrifuged and uncentrifuged CSF samples obtained in the laboratory to the results obtained at point of care; results of samples diluted 1:4 were compared in a subset.
Results:
The diagnostic sensitivity of a reactive CSF-Syphicheck (62%-64%) and the diagnostic specificity of a CSF-Syphicheck titer at or above 1:4 (79%-81%) were equivalent to the CSF-VDRL (54%-69% sensitivity, 73%-75% specificity) for laboratory and clinical neurosyphilis diagnoses. The CSF-Syphicheck normalized after neurosyphilis therapy similarly to the CSF-VDRL. The modified CSF-Syphicheck performed well at the point of care, albeit with better performance on cell-free compared with uncentrifuged CSF.
Conclusions:
Cerebrospinal fluid treponemal ICSTs hold promise for point-of-care neurosyphilis diagnosis in regions where the CSF-VDRL is not available. Further study should address the performance of CSF ICSTs in resource-limited settings.
More Related Videos
Related Concept Videos
Myasthenia Gravis: Diagnostic Tests
The edrophonium test is a diagnostic tool for myasthenia gravis. It involves...
Pulmonary Tuberculosis IV
Several diagnostic approaches are used to detect TB. The conventional method is the Tuberculin Skin Test (TST), also known as the Mantoux test. However, this method has...
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or...