Related Experiment Video
Updated: Apr 19, 2026

Inactivation of Pathogens via Visible-Light Photolysis of Riboflavin-5′-Phosphate
Published on: April 6, 2022
Action spectra for validation of pathogen disinfection in medium-pressure ultraviolet (UV) systems
Sara E Beck1, Harold B Wright2, Thomas M Hargy3
1Department of Civil, Environmental, and Architectural Engineering, University of Colorado Boulder, UCB 428, Boulder, CO 80309, USA.
Abstract:
Ultraviolet (UV) reactors used for disinfecting water and wastewater must be validated and monitored over time. The validation process requires understanding the photochemical properties of the pathogens of concern and the challenge microorganisms used to represent them. Specifically for polychromatic UV systems, the organisms' dose responses to UV light and their sensitivity across the UV spectrum must be known. This research measured the UV spectral sensitivity, called action spectra, of Cryptosporidium parvum, and MS2, T1UV, Q Beta, T7, and T7m Coliphages, as well as Bacillus pumilus spores. A tunable laser from the National Institute of Standards and Technology was used to isolate single UV wavelengths at 10 nm intervals between 210 and 290 nm. Above 240 nm, all bacteria and viruses tested exhibited a relative peak sensitivity between 260 and 270 nm. Of the coliphage, MS2 exhibited the highest relative sensitivity below 240 nm, relative to its sensitivity at 254 nm, followed by Q Beta, T1UV, T7m and T7 coliphage. B. pumilus spores were more sensitive to UV light at 220 nm than any of the coliphage. These spectra are required for calculating action spectra correction factors for medium pressure UV system validation, for matching appropriate challenge microorganisms to pathogens, and for improving UV dose monitoring. Additionally, understanding the dose response of these organisms at multiple wavelengths can improve polychromatic UV dose calculations and enable prediction of pathogen inactivation from wavelength-specific disinfection technologies such as UV light emitting diodes (LEDs).
More Related Videos
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
UV–Vis Spectrometers
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Cleaning, Sterilization, and Disinfection
Cleaning
The cleaning process usually involves using water with detergents or enzymatic cleaner and removing foreign material from objects and surfaces, including organic material such as body fluids or inorganic material like soil. Cleaning is performed before high-level disinfection and sterilization because foreign materials on the cover of the devices interfere with process...
Chemical Agents for Microbial Control

