Measuring the Complete-arch Distortion of an Optical Dental Impression
Published on: May 30, 2019
8.2K
Strain gauges's analysis on implant-retained prosthesis' cast accuracy
Mariana A Rodrigues1, Leonardo F Luthi, Jessica Mfk Takahashi
1Department of Periodontology and Prosthodontics, Piracicaba Dental School, Campinas State University (UNICAMP), Piracicaba, São Paulo, Brazil.
Summary
Four mold filling techniques for implant prostheses were evaluated. Results showed no significant difference in misfit, but one technique reduced strain, indicating its efficiency for better implant rehabilitation.
Area of Science:
- Dental prosthodontics
- Biomaterials engineering
- Implant dentistry
Background:
- Accurate casts are crucial for successful implant prosthesis rehabilitation.
- Proper casting minimizes strain on implants and improves structural integrity.
Purpose of the Study:
- To assess the precision of four distinct mold filling techniques.
- To validate a precise method for evaluating these techniques.
Main Methods:
- Forty casts were created using a metallic matrix for three-unit implant-retained prostheses.
- Four techniques were tested: single-portion, two-step, latex cylinder, and analog joining.
- Marginal misfit and strain forces were evaluated using optical microscopy and strain gauges.
Main Results:
- No statistically significant difference was found in misfit values across the four techniques (P = 0.979).
- Significant differences in strain were observed between the latex cylinder and analog joining techniques (P = 0.027).
Conclusions:
- The analog joining technique demonstrated comparable efficiency to conventional methods.
- Strain gauge methodology proved accurate for evaluating cast distortion and strain.
- No correlation was established between strain and marginal misfit.
Related Concept Videos
Measurements of Strain
2.8K
Strain quantifies the deformation of a material under force, typically measured as normal strain, which represents the change in length when compared with the original length. Electrical strain gauges are used for enhanced accuracy. These devices consist of a conductive wire mounted on a paper backing that adheres to the material's surface. These gauges operate on the piezoresistive effect, where the wire's electrical resistance changes in response to mechanical deformation. The strain...
2.8K
Design Example: Strain Gauge Bridge or Wheatstone Bridge
1.3K
The utilization of strain gauges as transducers for converting mechanical strain into electrical signals is a common practice in various engineering applications. These strain gauges are frequently integrated into Wheatstone bridge circuits to accurately measure parameters such as force or pressure. Within this context, each element within the circuit exhibits a resistance that undergoes subtle variations when subjected to mechanical strain. The primary objective is to convert minuscule...
1.3K
Temperature Dependent Deformation
677
In a nonhomogeneous rod made up of steel and brass, restrained at both ends and subjected to a temperature change, several steps are involved in calculating the stress and compressive load. Due to the problem's static indeterminacy, one end support is disconnected, allowing the rod to experience the temperature change freely. Next, an unknown force is applied at the free end, triggering deformations in the rod's steel and brass portions. These deformations are then calculated and added...
677