Related Experiment Video
Updated: Apr 19, 2026

Implantation of the Syncardia Total Artificial Heart
Published on: July 18, 2014
Concomitant aortic valve procedures in patients undergoing implantation of continuous-flow left ventricular assist
Jason O Robertson1, David C Naftel2, Susan L Myers2
1Division of Cardiothoracic Surgery, Washington University, St. Louis, Missouri.
Background:
Management of existing aortic insufficiency (AI) and mechanical aortic valves in patients undergoing left ventricular assist device (LVAD) implantation remains controversial. Surgical options to address these issues include closure, repair or replacement of the valve.
Methods:
Continuous-flow LVAD/biventricular VAD patients entered into the INTERMACS database between June 2006 and December 2012 were included (n = 5,344) in this analysis. Outcomes were compared between patients who underwent aortic valve (AV) closure (n = 125), repair (n = 95) and replacement (n = 85).
Results:
Among patients who underwent an AV procedure, actuarial survival was significantly reduced for AV closures (63.2%) compared with AV repairs (76.8%) and replacements (71.8%) (p = 0.0003). Differences were greater between groups when only INTERMACS Level 1 or 2 patients were analyzed (p = 0.003). After multivariate adjustment, AV closure remained a significant risk factor for mortality (hazard ratio = 1.87, 95% confidence interval 1.39 to 2.53, p < 0.0001). At 6 to 12 months post-operatively, moderate to severe AI developed in 19%, 5%, 9% and 10% of patients with available echocardiography who underwent repair, closure, replacement and no intervention, respectively (p < 0.0001). Competing outcomes demonstrate that, at 1-year, fewer patients with AV closures were transplanted compared with patients with repairs/replacements (14% vs 19%). No differences were observed between groups with respect to cause of death, re-hospitalization, right heart failure or stroke.
Conclusions:
AV closure was associated with increased mortality when compared with repair or replacement in patients with AI who underwent LVAD insertion. The reasons for this association require further investigation. This is the largest study to date to examine concomitant AV procedures in patients undergoing LVAD insertion.
Related Concept Videos
Aortic Regurgitation III: Medical Management
Cardiac Catheterization III: Left Heart Catheterization
Cardiomyopathy V: Interprofessional Care
Mitral Stenosis III: Medical Management
Aortic Regurgitation IV: Nursing Management