Related Experiment Video
Updated: Apr 19, 2026

Use of Two Intracorporeal Ventricular Assist Devices As a Total Artificial Heart
Published on: May 11, 2018
Crossover study of proportional assist versus assist control ventilation
Prashanth Bhat1, Deena-Shefali Patel1, Simon Hannam1
1Division of Asthma, Allergy and Lung Biology, MRC Centre for Allergic Mechanisms in Asthma, King's College London, London, UK.
Objective:
To test the hypothesis that in very prematurely born infants remaining ventilated beyond the first week, proportional assist ventilation (PAV) compared with assist control ventilation (ACV) would be associated with reduced work of breathing, increased respiratory muscle strength and less ventilator-infant asynchrony which would be associated with improved oxygenation.
Design:
Randomised crossover study.
Setting:
Tertiary neonatal unit.
Patients:
12 infants with a median gestational age of 25 (range 24-26) weeks were studied at a median of 43 (range 8-86) days.
Interventions:
Infants were studied for 1 h each on PAV and ACV in random order.
Main Outcome Measures:
At the end of each hour, the work of breathing (assessed by measuring the diaphragmatic pressure time product), thoracoabdominal asynchrony and respiratory muscle strength (maximal inspiratory pressure, maximal expiratory pressure (Pemax) and maximal transdiaphragmatic pressure (Pdimax)) were assessed. Blood gas analysis was performed and the oxygenation index (OI) calculated.
Results:
After 1 h on PAV compared with 1 h on ACV, the median OI (5.55 (range 5-11) vs 10.10 (range 7-16), p=0.002) and PTP levels were lower (217 (range 59-556) cm H2O.s/min vs 309 (range 55-544) cm H2O.s/min, p=0.005), while Pdimax (44.26 (range 21-66) cm H2O vs 37.9 (range 19-45) cm H2O, p=0.002) and Pemax (25.6 (range 6.5-42) cm H2O vs 15.9 (range 3-35) cm H2O levels p=0.010) were higher.
Conclusions:
These results suggest that PAV compared with ACV may have physiological advantages for prematurely born infants who remain ventilated after the first week after birth.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation I: Indication and Settings
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement: