Related Experiment Video
Updated: Apr 19, 2026

Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Effect of endodontic sealers on push-out bond strength of cemented fiber posts
Objective:
The purpose of this study was to compare the effect of eugenol-based and resin-based endodontic sealers on the push-out bond strengths of prefabricated fiber posts luted with different resin cements.
Method And Materials:
Ninety prefabricated fiber posts were luted into extracted singlerooted teeth with one of three resin cements (Variolink II, ParaCore, or Rely X Unicem). Each group was subdivided into three groups with 10 teeth each. The first two groups were obturated with gutta percha and one of two eugenol-based endodontic sealers (Endofil or TubliSeal) each. The third group was obturated with gutta percha and (AH26) resin-based root canal sealer. Push-out tests were performed in a universal testing machine by applying a load speed at 0.5 mm/min by using a 1-mm-diameter metallic plunger which induced a load in an apical to coronal direction. The maximum value for post dislodgement (in Newtons) was recorded. Data were collected and statistically analyzed using two-way ANOVA and Tukey multiple comparison tests (α = .05).
Results:
The highest mean bond strength values were recorded for the AH26 sealer group (non-eugenol sealer) luted with Rely X Unicem resin cement (mean ± SD = 326.1 ± 66.1 N), while the lowest mean bond strength values were observed with posts luted with Variolink II resin cement into canals obturated with gutta-percha and Endofil (eugenol-based) sealer (90.3 ± 25.2 N). There was no significant difference between the means of push-out strengths for the Endofil and TubliSeal groups (P = .745).
Conclusion:
Eugenol-based sealers (Endofil and TubliSeal) significantly reduced the push-out bond strength of prefabricated fiber posts luted with resin cement.
More Related Videos
Related Concept Videos
Bonding and Strength of Aggregate
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Porosity in Cement Paste
The balance of water to cement in the mix is...
Microcracking in Concrete

