Related Experiment Video
Updated: Apr 19, 2026

Field Postmortem Rabies Rapid Immunochromatographic Diagnostic Test for Resource-Limited Settings with Further Molecular Applications
Published on: June 29, 2020
Testing for Partial RhD with a D-Screen Diagast Kit in Moroccan Blood Donors with Weak D Expression
Z Kabiri1, M Benajiba2, K Hajjout3
1Centre National de Transfusion Sanguine, rue Lamfadel Cherkaoui, Madinat Al Irfane, P.O. Box 180, 10000 Rabat, Morocco ; Departement de Biologie, Faculté des Sciences, University MDV Rabat Agdal, 1014 Rabat, Morocco.
Abstract:
The aim of this study was to search for the partial D phenotype in Moroccan blood donors with weak D expression. The study included 32 samples with weak D phenotype, and partial D category red blood cells were detected with the D-Screen Diagast kit, which consists in 9 monoclonal anti-D antibodies specific for the most common categories of partial D. Among the 32 samples studied, we identified 13 specific reactions to a partial D antigen (3 DVI, 2 DVa, 2 DIII((a,b,c)), and 6 DVII), with 8 reactions suggesting a weak D and 11 reactions providing no formal argument in favor of a partial D antigen. This work can be used to validate the performance of the anti-D reagent and to improve the safety of transfusion of red blood cells from donors expressing the partial D antigen by integrating the finding into the recipient file with a recommendation concerning the appropriate care.
Related Concept Videos
Rh Blood Group
Blood Typing
Antigens are protein molecules that reside on the surface of red blood cells (RBCs). The ABO and Rh blood typing systems target...