[The field radiometric calibration and validation of ZY-3 multispectral sensor]
Abstract:
A field calibration campaign of ZY-3 multispectral sensor (MUS) was performed by the China Center for Resources Satellite Data and Application at the Dunhuang site. The reflectance-based method with two-point sites was used to obtain MUS absolute calibration coefficients in 2013. Compared to the calibration results in 2012, the calibration coefficients in 2013 changed by about 1%-8.5% in different bands. The results were also validated by intercalibration method using the Landsat 8 Operational Land Imager (OLI) data. It shows largely good consistency between field calibration and intercalibration. It was concluded that the absolute calibration coefficients were highly reliable.
Related Concept Videos
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Calibration Curves: Correlation Coefficient
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...