Related Experiment Video
Updated: Apr 19, 2026

ARL Spectral Fitting as an Application to Augment Spectral Data via Franck-Condon Lineshape Analysis and Color Analysis
Published on: August 19, 2021
[Research on algorithm for self-absorption correction based on multi-particles LIBS spectra]
Abstract:
In order to overcome the influence of self-absorption on quantitative analysis, the optimizing process of very fast simulated annealing algorithm was studied. According to basic theory of plasma emission spectrum, a new algorithm for self-absorpton correction based on multi-particles spectra was proposed, and the algorithm flowchart was given. With the self-absorption correction algorithm mentioned above, the spectra of refining slag and blast furnace slag were corrected. The effect of self-ab sorption correction on the quantitative analysis results was analyzed based on calibration free method. Comparison of Boltzmann plots before and after self-absorption correction indicated that the plasma temperatures calculated with spectra after self-absorption correction tended to be uniform, and remained stable around 11,600 K. The Boltzmann plots constructed with plasma spectra of the same particle after self-absorption correction indicated that the intercepts were almost the same except for one group data. With calibration free method and spectra after self-absorption correction, the contents of components in slag were analyzed. For refining slag, quantitative analysis precision of MgO was low. If ignoring the existence of MgO, the relative errors of quantitative analysis results of CaO, Al2 O3 and SiOs were much smaller. For blast furnace slag in which the content of MgO was 8.49%, the relative error of quantitative analysis result of Al2 O3 was 2.38%, which was the smallest. And the relative error of quantitative analysis result of MgO was 28.27%, which was still the biggest.
More Related Videos
Related Concept Videos
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
NMR Spectrometers: Resolution and Error Correction
Molecular Spectroscopy: Absorption and Emission
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to...
Atomic Absorption Spectroscopy: Overview
When irradiated by EMR of a particular wavelength, these...
Atomic Absorption Spectroscopy: Atomization Methods