Related Experiment Video
Updated: Apr 19, 2026

A Simple Method for Automated Solid Phase Extraction of Water Samples for Immunological Analysis of Small Pollutants
Published on: January 1, 2016
Stir fabric phase sorptive extraction for the determination of triazine herbicides in environmental waters by liquid
Mercedes Roldán-Pijuán1, Rafael Lucena1, Soledad Cárdenas1
1Department of Analytical Chemistry, Institute of Fine Chemistry and Nanochemistry, Marie Curie Building, Campus de Rabanales, University of Córdoba, 14071 Córdoba, Spain.
Abstract:
Stir fabric phase sorptive extraction (SFPSE), which integrates sol-gel hybrid organic-inorganic coated fabric phase sorptive extraction media with a magnetic stirring mechanism, is presented for the first time. Two flexible fabric substrates, cellulose and polyester were used as the host matrix for three different sorbents e.g., sol-gel poly(tetrahydrofuran), sol-gel poly(ethylene glycol), and sol-gel poly(dimethyldiphenylsiloxane). The new microextraction device has been analytically evaluated using triazine herbicides as model compounds. The factors affecting the extraction efficiency of SFPSE have been investigated and the optimal extraction conditions have been determined. Under these optimum conditions, the limits of quantification (LOQs) for sol-gel poly(ethylene glycol) coated SFPSE device in combination with UPLC-DAD for the analysis of the seven triazine herbicides were in the range of 0. 26-1.50μg/L with precision (relative standard deviation) at 2μg/L concentration ranging from 1.4-4.8% (intra-day, n=5) and 6.8-11.8% (inter-day, n=3). Enrichment factors were found between 444 and 1411 (compared to 2000 theoretical maximum). Absolute extraction recoveries were in the range of 22.2-70.5%. The developed method was applied for the determination of selected triazine herbicides from three river water samples. Relative recoveries of the target analytes, in the range from 75 to 126%, were found to be satisfactory. The combination of SFPSE with LC-MS/MS allows the improvement of the method sensitivity to the range from 0.015μg/L to 0.026μg/L with precision better than 10.8% expressed as relative standard deviation (RSD).
More Related Videos
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
04:17Analysis of Organochlorine Pesticides in a Soil Sample by a Modified QuEChERS Approach Using Ammonium Formate
Published on: January 20, 2023
Related Concept Videos
High-Performance Liquid Chromatography: Types of Detectors
High-Performance Liquid Chromatography: Elution Process
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process:
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Analyte Adsorption and Distribution
Extraction: Advanced Methods