Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
μGC × μGC: comprehensive two-dimensional gas chromatographic separations with microfabricated components
William R Collin1, Amy Bondy, Dibyadeep Paul
1Department of Chemistry, University of Michigan , Ann Arbor, Michigan 48109-1055, United States.
Abstract:
The development and characterization of a microanalytical subsystem comprising silicon-micromachined first- and second-dimension separation columns and a silicon-micromachined thermal modulator (μTM) for comprehensive two-dimensional (i.e., μGC × μGC) separations are described. The first dimension consists of two series-coupled 3.1 cm × 3.1 cm μcolumn chips with etched channels 3 m long and 250 μm × 140 μm in cross section, wall-coated with a poly(dimethylsiloxane) (PDMS) stationary phase. The second dimension consists of a 1.2 cm × 1.2 cm μcolumn chip with an etched channel 0.5 m long and 46 μm × 150 μm in cross section wall-coated with either a trigonal tricationic room-temperature ionic liquid (RTIL) or a commercial poly(trifluoropropylmethyl siloxane) (OV-215) stationary phase. The two-stage, cryogen-free μTM consists of a Si chip containing two series-coupled, square spiral channels 4.2 cm and 2.8 cm long and 250 μm × 140 μm in cross section wall-coated with PDMS. Conventional injection methods and flame ionization detection were used. Temperature-ramped separations of a simple alkane mixture using the RTIL-coated second-dimension ((2)D) μcolumn produced reasonably good peak shapes and modulation numbers; however, strong retention of polar compounds on the RTIL-coated (2)D μcolumn led to excessively broad peaks with low (2)D resolution. Substituting OV-215 as the (2)D μcolumn stationary phase markedly improved the performance, and a structured 22 min chromatogram of a 36-component mixture spanning a vapor pressure range of 0.027 to 13 kPa was generated with modulated peak fwhm (full width at half-maximum) values ranging from 90 to 643 ms and modulation numbers of 1-6.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
08:37Measurement of H2S in Crude Oil and Crude Oil Headspace Using Multidimensional Gas Chromatography, Deans Switching and Sulfur-selective Detection
Published on: December 10, 2015
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gas Chromatography: Types of Detectors-II