A Sample Preparation Pipeline for Microcrystals at the VMXm Beamline
Published on: June 17, 2021
Energy optimization of a regular macromolecular crystallography beamline for ultra-high-resolution crystallography
Gerd Rosenbaum1, Stephan L Ginell1, Julian C H Chen2
1Structural Biology Center, Biosciences Division, Argonne National Laboratory, Argonne, IL 60439, USA.
Abstract:
A practical method for operating existing undulator synchrotron beamlines at photon energies considerably higher than their standard operating range is described and applied at beamline 19-ID of the Structural Biology Center at the Advanced Photon Source enabling operation at 30 keV. Adjustments to the undulator spectrum were critical to enhance the 30 keV flux while reducing the lower- and higher-energy harmonic contamination. A Pd-coated mirror and Al attenuators acted as effective low- and high-bandpass filters. The resulting flux at 30 keV, although significantly lower than with X-ray optics designed and optimized for this energy, allowed for accurate data collection on crystals of the small protein crambin to 0.38 Å resolution.
Related Concept Videos
X-ray Crystallography
Diffraction
Diffraction is the change in the direction of travel experienced by an electromagnetic wave when it encounters a physical barrier whose dimensions are comparable to those of the wavelength of the light. X-rays are electromagnetic radiation with wavelengths about as long as the distance between neighboring...