Related Experiment Video
Updated: Apr 19, 2026

18F-Labeling of Radiotracers Functionalized with a Silicon Fluoride Acceptor SiFA for Positron Emission Tomography
Published on: January 11, 2020
18F-sodium fluoride PET/CT in oncology: an atlas of SUVs
Nathanael Sabbah1, Tatianie Jackson, Camila Mosci
1From the Divisions of *Nuclear Medicine and †Molecular Imaging, Department of Radiology, Stanford University Medical Center, Stanford, CA.
Purpose:
The purpose of this study was to analyze the distribution of 18F Sodium Fluoride (18F-NaF) uptake in the normal skeleton, benign and malignant bone lesions, and extraskeletal tissues, using semiquantitative SUV measurements.
Patients And Methods:
We retrospectively analyzed data from 129 patients who had 18F-NaF PET/CT at our institution for an oncological diagnosis between 2007 and 2014. There were 99 men and 30 women, 19 to 90 years old (mean [SD], 61.5 [15.5]). The range, average, and SD of SUV were measured for normal bone and extraskeletal tissues uptake for the entire patient population. A separate statistical analysis was performed to compare group A, which corresponds to the population of patient with no 18F-NaF-avid metastatic lesions, and group B, which corresponds to the population of patient with 18F-NaF-avid metastatic lesions. We also measured SUV max and SUV mean for bony metastases and degenerative changes
Results:
The PET/CT images were acquired at 30 to 169 minutes (mean [SD], 76.5 [22.8]) after injection of 3.9 to 13.6 mCi (mean [SD], 7.3 [2.4]) of 18F-NaF. The range and mean (SD) of SUV max for 18F-NaF-avid metastasis were 4.5 to 103.3 and 25.9 (16.6) and for 18F-NaF-avid degenerative changes were 3.3 to 52.1 and 16.5 (7.9), respectively.
Conclusions:
Various skeletal sites have different normal SUVs. Skeletal metastases have different SUVs when compared with benign findings such as degenerative changes.
More Related Videos
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
![Quantitative [18F]-Naf-PET-MRI Analysis for the Evaluation of Dynamic Bone Turnover in a Patient with Facetogenic Low Back Pain](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58491.jpg&w=3840&q=50)
![Semi-quantitative Assessment Using [18F]FDG Tracer in Patients with Severe Brain Injury](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F58641.jpg&w=3840&q=50)