Updated: Apr 19, 2026
![PET Imaging of Neuroinflammation Using [11C]DPA-713 in a Mouse Model of Ischemic Stroke](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F57243.jpg&w=3840&q=50)
PET Imaging of Neuroinflammation Using [11C]DPA-713 in a Mouse Model of Ischemic Stroke
Published on: June 14, 2018
Image derived input function for [18F]-FEPPA: application to quantify translocator protein (18 kDa) in the human
Rostom Mabrouk1, Pablo M Rusjan1, Romina Mizrahi2
1Research Imaging Centre, Centre for Addiction and Mental Health (CAMH), Toronto, Ontario, Canada.
Independent component analysis (ICA) offers a more reliable method for extracting the input function in [18F]-FEPPA positron emission tomography (PET) imaging compared to carotid signal (CS) methods, improving translocator protein (TSPO) quantification in the brain.
Area of Science:
- Neuroimaging
- Radiochemistry
- Nuclear Medicine
Background:
- Automatic blood sampling system (ABSS) is the gold standard for input function (IF) extraction in [18F]-FEPPA PET imaging.
- Accurate IF is crucial for quantifying translocator protein (TSPO) in the human brain.
- Image-based IF extraction methods offer potential alternatives to invasive ABSS.
Purpose of the Study:
- To compare the performance of two image-based IF extraction methods (carotid signal [CS] and independent component analysis [ICA]) against the ABSS gold standard.
- To evaluate the reliability of these methods for quantifying TSPO in various human brain regions.
Main Methods:
- Collected [18F]-FEPPA PET scans from 18 healthy volunteers.
- Extracted IFs using direct delineation of the internal carotid signal (CS-IF) and independent component analysis (ICA-IF).
- Compared estimated total distribution volume (V(T)) values derived from CS-IF and ICA-IF to reference V(T) from ABSS-IF across multiple brain regions.
Main Results:
- ICA-IF demonstrated higher reliability than CS-IF for V(T) estimation across all evaluated brain regions.
- Frontal cortex analysis showed a strong regression slope for ICA-IF (r² = 0.91, p<0.05) compared to CS-IF (r² = 0.71, p<0.05).
- ICA-IF provided more consistent and accurate TSPO quantification compared to CS-IF.
Conclusions:
- Image-based IF extraction using ICA is a reliable alternative to ABSS for [18F]-FEPPA PET.
- ICA-IF improves the accuracy and consistency of TSPO quantification in the human brain.
- This method enhances the utility of PET imaging for studying TSPO in neurological research.