EZ-IO(®) intraosseous device implementation in German Helicopter Emergency Medical Service
Matthias Helm1, Benedikt Haunstein1, Thomas Schlechtriemen2
1Department of Anaesthesiology & Intensive Care Medicine - Section Emergency Medicine/HEMS "Christoph 22", Armed Forces Medical Centre Ulm, Germany.
Background:
Intraosseous access (IO) is a rapid and safe alternative when peripheral venous access is difficult. Our aim was to summarize the first three years experience with the use of a semi-automatic IO device (EZ-IO(®)) in German Helicopter Emergency Medical Service (HEMS).
Methods:
Included were all patients during study period (January 2009-December 2011) requiring an IO access performed by HEMS team. Outcome variables were IO rate, IO insertion success rates, site of IO access, type of EZ-IO(®) needle set used, strategy of vascular access, procedure related problems and operator's satisfaction.
Results:
IO rate was 0.3% (348/120.923). Overall success rate was 99.6% with a first attempt success rate of 85.9%; there was only one failure (0.4%). There were three insertion sites: proximal tibia (87.2%), distal tibia (7.5%) and proximal humerus (5.3%). Within total study group IO was predominantly the second-line strategy (39% vs. 61%, p<0.001), but in children<7 years, in trauma cases and in cardiac arrest IO was more often first-line strategy (64% vs. 28%, p<0.001; 48% vs. 34%, p<0.032; 50% vs. 29%, p<0.002 respectively). Patients with IO access were significantly younger (41.7±28.7 vs. 56.5±24.4 years; p<0.001), more often male (63.2% vs. 57.7%; p=0.037), included more trauma cases (37.3% vs. 30.0%; p=0.003) and more often patients with a NACA-Score≥5 rating (77.0% vs. 18.6%; p<0.001). Patients who required IO access generally presented with more severely compromised vital signs associated with the need for more invasive resuscitation actions such as intubation, chest drains, CPR and defibrillation. In 93% EZ-IO(®) needle set handling was rated "good". Problems were reported in 1.6% (needle dislocation 0.8%, needle bending 0.4% and parafusion 0.4%).
Conclusions:
The IO route was generally used in the most critically ill of patients. Our relatively low rate of usage would indicate that this would be compatible with the recommendations of established guidelines. The EZ-IO(®) intraosseous device proved feasible with a high success rate in adult and pediatric emergency patients in HEMS.
More Related Videos
Related Concept Videos
Oxygen Delivering System III: Tracheostomy and T-piece
Tracheostomy
A tracheostomy is a surgically created opening (stoma) in the anterior part of the trachea. It is used to establish a patient airway, bypass an upper airway obstruction, simplify the removal of secretions, permit long-term...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Cardiopulmonary Resuscitation II: ACLS Airway Management
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...