Related Experiment Video
Updated: Apr 19, 2026

A Finite Element Approach for Locating the Center of Resistance of Maxillary Teeth
Published on: April 8, 2020
Finite element analysis of the principles and loosening force of the conical telescopic crown: a computer-based study
C Fingerhut1, H J Schindler, K Schweizerhof
1Universitätklinikum Heidelberg.
Objectives:
The primary goal of the present finite element (FE) analysis of a special removable prosthesis, the conical telescopic crown (CTC), was to validate established results based on a rigid model of the CTC and to analyze its characteristic features as a function of the essential material and geometric parameters. Furthermore, the effectiveness of a new element, the composite stop (CS), was investigated.
Materials And Methods:
The study used an axisymmetric FE model containing the inner and outer crown including resin or ceramic veneer, the CS, the cement layer between the interior crown and the tooth, and the upper part of the tooth itself.
Results:
For a convergence angle (half-cone angle) α = 4 degrees and a moderate chewing force F = 150 N the loosening force decreased from - 50 N without to - 10 N with CS. Increasing α values yielded a decrease of the loosening force. Adherence between the inner (IC) and outer crown (OC) was achieved for all configurations (α = 2 degrees, 4 degrees, and 6 degrees), except for zirconium crowns with α = 6 degrees. In systems without CS, the maximum tensile stress in the veneer increased proportionally to F, but remained limited in those with CS.
Conclusions:
The angle a and the coefficient of static friction μ0 emerged as the decisive parameters of the CTC. The computed fitting/loosening behavior agreed well with results of a simple rigid-body model and experiments. The incorporation of a CS allows ceramic veneering of the outer crown.
Clinical Relevance:
The optimal angle α of the CTC is ascribed to a number of customary material combinations for IC and OC. The CS limits the loosening forces of the CTC to values which guarantee non-traumatic removal of the prosthesis.
More Related Videos
07:16Author Spotlight: Development of a Novel Finite Element Analysis Model for Improved Orthognathic Surgical Techniques
Published on: October 20, 2023
07:09In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
Related Concept Videos
Eccentric Axial Loading in a Plane of Symmetry
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical...
Thin-Walled Hollow Shafts
Euler's Formula to Columns: Problem Solving
The system comprises two vertical rigid bars, AB and BC, of...
Method of Sections: Problem Solving II