Treatment of amoxicillin by O3/Fenton process in a rotating packed bed

Mo Li1, Zequan Zeng2, Yingwen Li1

  • 1State Key Laboratory of Organic-Inorganic Composites, Beijing University of Chemical Technology, Beijing 100029, PR China; Research Center of the Ministry of Education for High Gravity Engineering and Technology, Beijing University of Chemical Technology, Beijing 100029, PR China.

Related Concept Videos

Bioreactor Controls-II01:18

Bioreactor Controls-II

In aerobic fermentations, oxygen is vital for microbial growth and metabolite production. Since air comprises only about 20% oxygen and the gas is poorly soluble in water—just 9 ppm at 20°C—supplying sufficient oxygen becomes a critical challenge, especially in high-demand processes like yeast growth or citric acid production. Even a fully saturated broth may offer only a few seconds of oxygen availability.To address this, sterile or scrubbed air is introduced into the...
68
Oxidative Cleavage of Alkenes: Ozonolysis01:46

Oxidative Cleavage of Alkenes: Ozonolysis

In ozonolysis, ozone is used to cleave a carbon–carbon double bond to form aldehydes and ketones, or carboxylic acids, depending on the work-up.
Ozone is a symmetrical bent molecule stabilized by a resonance structure.
14.0K
Production of Antibiotics01:27

Production of Antibiotics

Penicillin, one of the earliest and most widely used antibiotics, is produced industrially by the filamentous fungus Penicillium chrysogenum. Large stirred-tank bioreactors ranging from tens to hundreds of thousands of liters maintain tightly controlled temperature, pH, and dissolved oxygen conditions to support fungal metabolism and maximize antibiotic yield. Penicillin is a secondary metabolite, synthesized primarily during the stationary growth phase, which requires a carefully managed...
198
Methods of Sterilization II: Chemical Methods01:30

Methods of Sterilization II: Chemical Methods

In healthcare, the chemical method of sterilization uses chemical sterilants to treat surgical instruments and medical supplies to help prevent the transmission of infectious pathogens to patients. Due to heat sensitivity, most medical supplies and equipment should not be exposed to high temperatures. These parts include rubber, plastic, glass, and other similar elements.
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
11.2K
Oxidation of Alkenes: Syn Dihydroxylation with Osmium Tetraoxide02:44

Oxidation of Alkenes: Syn Dihydroxylation with Osmium Tetraoxide

Alkenes are converted to 1,2-diols or glycols through a process called dihydroxylation. It involves the addition of two hydroxyl groups across the double bond with two different stereochemical approaches, namely anti and syn. Dihydroxylation using osmium tetroxide progresses with syn stereochemistry.
13.9K