Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Computed Tomography01:10

Computed Tomography

9.7K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
9.7K
Distributions to Estimate Population Parameter01:26

Distributions to Estimate Population Parameter

5.8K
The accurate values of population parameters such as population proportion, population mean, and population standard deviation (or variance) are usually unknown. These are fixed values that can only be estimated from the data collected from the samples. The estimates of each of these parameters are sample proportion, the sample mean, and sample standard deviation (or variance). To obtain the values of these sample statistics, data are required that have particular distribution and central...
5.8K
Maxwell-Boltzmann Distribution: Problem Solving01:20

Maxwell-Boltzmann Distribution: Problem Solving

3.2K
Individual molecules in a gas move in random directions, but a gas containing numerous molecules has a predictable distribution of molecular speeds, which is known as the Maxwell-Boltzmann distribution, f(v).
This distribution function f(v) is defined by saying that the expected number N (v1,v2) of particles with speeds between v1 and v2 is given by
3.2K
Cluster Sampling Method01:20

Cluster Sampling Method

15.8K
Appropriate sampling methods ensure that samples are drawn without bias and accurately represent the population. Because measuring the entire population in a study is not practical, researchers use samples to represent the population of interest.
To choose a cluster sample, divide the population into clusters (groups) and then randomly select some of the clusters. All the members from these clusters are in the cluster sample. For example, if you randomly sample four departments from your...
15.8K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Microscopic intramural spread in patients with rectal cancer after neoadjuvant chemoradiation.

Clinical and translational radiation oncology·2025
Same author

Brachytherapy treatment verification using gamma radiation from the internal treatment source combined with an imaging panel-a phantom study.

Physics in medicine and biology·2021
Same author

The Accessory muscles of the Axilla.

Acta orthopaedica Belgica·2020
Same author

Bridging the gap between micro- and macro-scales in medical imaging with textural analysis - A biological basis for CT radiomics classifiers?

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)·2020
Same author

Monte Carlo kilovoltage X-ray tube simulation: A statistical analysis and compact simulation method.

Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics (AIFB)·2020
Same author

Automatic Quality Assessment of Transperineal Ultrasound Images of the Male Pelvic Region, Using Deep Learning.

Ultrasound in medicine & biology·2019
Same journal

Correction to "On the shape of the radiation survival curve in tumor spheroids: The role of oxygen heterogeneity".

Medical physics·2026
Same journal

Multi-view constrained semi-supervised vertebra detection for 3D ultrasound spine volume.

Medical physics·2026
Same journal

Accuracy of quantitative <sup>177</sup>Lu SPECT/CT imaging: A systematic review.

Medical physics·2026
Same journal

Physics-constrained dual-domain network for CBCT reconstruction from orthogonal X-rays in gynecologic radiotherapy.

Medical physics·2026
Same journal

Decomposition-based harmonization for quantitative PET imaging across scanners and radiotracers.

Medical physics·2026
Same journal

Development and evaluation of an in vivo dose-based monitoring system for electron FLASH radiation therapy.

Medical physics·2026
See all related articles

Related Experiment Video

Updated: Apr 18, 2026

Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities
07:13

Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities

Published on: October 27, 2023

1.8K

Efficient scatter distribution estimation and correction in CBCT using concurrent Monte Carlo fitting.

G J Bootsma1, F Verhaegen2, D A Jaffray3

  • 1Radiation Medicine Program, Princess Margaret Cancer Centre, Toronto, Ontario M5G 2M9, Canada.

Medical Physics
|January 8, 2015
PubMed
Summary
This summary is machine-generated.

This study introduces a novel scatter correction algorithm for cone-beam CT (CBCT) that significantly reduces computation time and improves image quality. The concurrent Monte Carlo fitting (CMCF) method enhances contrast-to-noise ratio and reduces reconstruction error in medical imaging.

More Related Videos

Outer-Boundary Assisted Segmentation and Quantification of Trabecular Bones by an Imagej Plugin
09:36

Outer-Boundary Assisted Segmentation and Quantification of Trabecular Bones by an Imagej Plugin

Published on: March 14, 2018

9.9K
Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation
10:33

Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation

Published on: September 4, 2017

16.8K

Related Experiment Videos

Last Updated: Apr 18, 2026

Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities
07:13

Author Spotlight: An Efficient and Robust Software for Automated Fusion of Multiple Preclinical Imaging Modalities

Published on: October 27, 2023

1.8K
Outer-Boundary Assisted Segmentation and Quantification of Trabecular Bones by an Imagej Plugin
09:36

Outer-Boundary Assisted Segmentation and Quantification of Trabecular Bones by an Imagej Plugin

Published on: March 14, 2018

9.9K
Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation
10:33

Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation

Published on: September 4, 2017

16.8K

Area of Science:

  • Medical Physics
  • Image Reconstruction
  • Computational Imaging

Background:

  • X-ray scatter degrades image quality in cone-beam CT (CBCT).
  • Accurate scatter estimation is crucial for improving CBCT image fidelity.
  • Existing methods often face computational challenges or limitations in accuracy.

Purpose of the Study:

  • To present and demonstrate a novel scatter correction algorithm for CBCT.
  • To reduce the computational burden of scatter estimation using Monte Carlo (MC) simulations.
  • To improve the accuracy and efficiency of scatter correction in CBCT.

Main Methods:

  • Developed a concurrent Monte Carlo fitting (CMCF) algorithm combining multiple MC CBCT simulations.
  • Employed a concurrently evaluated fitting function to estimate scatter distribution.
  • Validated the CMCF method on simulated (anthropomorphic head and pelvis phantoms) and measured data (pelvis phantom and patient scans).

Main Results:

  • Pearson's correlation (r) was identified as a suitable goodness-of-fit metric.
  • The CMCF algorithm achieved accurate scatter fits with reduced computational time (over four orders of magnitude reduction in photon histories).
  • Scatter estimation was rapid (35-122 seconds on 16 cores).
  • Image quality improved: 10%-50% increase in contrast-to-noise ratio and <3% reconstruction error for simulated data.

Conclusions:

  • The CMCF algorithm offers a significant reduction in computation time for scatter estimation in CBCT.
  • The method effectively reduces statistical noise and the number of required MC simulations.
  • Scatter correction using CMCF improves reconstruction image quality for both simulated and real projection data.