Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Bladder cancer segmentation using u-net-based deep-learning.

Scientific reports·2026
Same author

Launching <i>BJR</i>|<i>Artificial intelligence</i>: an editorial.

BJR artificial intelligence·2026
Same author

Evaluating the reliability of large language models for clinical data extraction in bladder cancer prognosis.

Scientific reports·2025
Same author

Outcome Prediction Using Multi-Modal Information: Integrating Large Language Model-Extracted Clinical Information and Image Analysis.

Cancers·2024
Same author

Enhancing Early Lung Cancer Diagnosis: Predicting Lung Nodule Progression in Follow-Up Low-Dose CT Scan with Deep Generative Model.

Cancers·2024
Same author

AI and machine learning in medical imaging: key points from development to translation.

BJR artificial intelligence·2024

Related Experiment Video

Updated: Apr 18, 2026

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
13:44

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns

Published on: August 30, 2013

43.9K

Multiscale bilateral filtering for improving image quality in digital breast tomosynthesis.

Yao Lu1, Heang-Ping Chan1, Jun Wei1

  • 1Department of Radiology, University of Michigan, Ann Arbor, Michigan 48109.

Medical Physics
|January 8, 2015
PubMed
Summary

This study introduces a new image processing technique to improve the clarity of tiny calcium deposits in 3D breast X-ray scans. By separating image details into different frequency levels, the method boosts the visibility of these deposits while keeping the surrounding breast tissue sharp and natural.

Keywords:
image reconstructionnoise reductiondiagnostic radiologybreast cancer detection

Frequently Asked Questions

More Related Videos

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
15:48

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging

Published on: December 15, 2014

23.6K
Three-Dimensional Imaging of Tumor-Bearing Tissue Using the Iterative Bleaching Extends Multiplexity Approach
07:16

Three-Dimensional Imaging of Tumor-Bearing Tissue Using the Iterative Bleaching Extends Multiplexity Approach

Published on: April 25, 2025

937

Related Experiment Videos

Last Updated: Apr 18, 2026

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns
13:44

Detection of Architectural Distortion in Prior Mammograms via Analysis of Oriented Patterns

Published on: August 30, 2013

43.9K
Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging
15:48

Tracking the Mammary Architectural Features and Detecting Breast Cancer with Magnetic Resonance Diffusion Tensor Imaging

Published on: December 15, 2014

23.6K
Three-Dimensional Imaging of Tumor-Bearing Tissue Using the Iterative Bleaching Extends Multiplexity Approach
07:16

Three-Dimensional Imaging of Tumor-Bearing Tissue Using the Iterative Bleaching Extends Multiplexity Approach

Published on: April 25, 2025

937

Area of Science:

  • Medical imaging physics and multiscale bilateral filtering applications
  • Radiological science and diagnostic image processing

Background:

Detecting tiny calcium deposits within three-dimensional breast scans remains a difficult clinical task. High levels of background interference often obscure these small features during standard reconstruction processes. Traditional smoothing techniques frequently misidentify delicate tissue boundaries or small mass extensions as unwanted artifacts. This error leads to the unintended blurring of critical diagnostic information. No prior work had resolved the conflict between noise reduction and the preservation of subtle anatomical details. That uncertainty drove the development of advanced filtering strategies to improve diagnostic accuracy. Prior research has shown that standard approaches often prioritize global smoothing over local feature retention. This gap motivated the creation of a more sophisticated framework for image enhancement.

Purpose Of The Study:

The authors aimed to develop a novel regularization method to enhance the contrast-to-noise ratio of microcalcifications. This research addresses the difficulty of detecting small features within large and noisy breast volumes. Most existing techniques treat subtle anatomical details as noise due to their low gradient values. This limitation often results in the loss of critical diagnostic information during the reconstruction process. The team sought to preserve the integrity of mass margins while simultaneously suppressing background interference. They designed a framework that exploits the multiscale nature of the image data. This effort was motivated by the need for clearer visualization of suspicious findings in clinical breast imaging. The study focuses on optimizing the simultaneous algebraic reconstruction technique to achieve better diagnostic outcomes.

Main Methods:

The investigators utilized a GE GEN2 prototype system to acquire projections at twenty-one distinct angles. Their review approach involved comparing the new method against the non-convex total p-variation technique. The team processed scans from both a heterogeneous phantom and human subjects. They implemented Laplacian pyramid decomposition at the end of every iteration of the reconstruction algorithm. This design allowed for the independent treatment of different frequency bands within each slice. The researchers calculated the contrast-to-noise ratio to evaluate the visibility of small features. They also assessed the full width at half maximum to verify the sharpness of mass spiculations. All quantitative comparisons were performed against a baseline reconstruction that lacked any regularization.

Main Results:

The proposed method achieved the highest contrast-to-noise ratio for microcalcifications among all tested approaches. The authors report that their technique successfully reduced contouring artifacts compared to the total p-variation method. Measurements showed that the full width at half maximum for calcifications remained comparable to non-regularized images. The results indicate that mass spiculations maintained their sharpness throughout the reconstruction process. The new approach proved superior to both the total p-variation and non-regularized methods for enhancing small diagnostic markers. Data from the heterogeneous phantom confirmed that the structured background remained preserved after filtering. The study demonstrates that the filtering framework effectively balances noise suppression with the retention of fine anatomical details. These findings highlight a significant improvement in image quality for complex breast volumes.

Conclusions:

The authors propose that their novel filtering approach effectively balances noise suppression with feature preservation. Synthesis and implications suggest that this technique outperforms existing non-convex regularization methods in clinical settings. The researchers demonstrate that their strategy maintains the sharpness of complex mass boundaries during reconstruction. This work indicates that frequency-based decomposition allows for the selective enhancement of small diagnostic markers. The evidence supports the use of this method to improve the visibility of calcifications in heterogeneous breast tissue. These findings imply that the proposed framework provides a robust alternative to traditional algebraic reconstruction techniques. The authors conclude that their approach minimizes common artifacts while maximizing the clarity of relevant clinical findings. Future clinical utility may benefit from the improved contrast-to-noise ratios observed in this investigation.

The researchers propose a frequency-based decomposition strategy. By applying bilateral filtering only to high-frequency bands, the method selectively boosts calcium deposits while leaving low-frequency tissue structures untouched during the algebraic reconstruction process.

The authors utilize Laplacian pyramid decomposition to separate image data into distinct frequency layers. This tool allows the system to distinguish between fine-scale diagnostic features and broader anatomical backgrounds.

The team explains that applying regularization to low-frequency bands would blur delicate mass margins. Therefore, they restrict the filtering process to high-frequency components to ensure that subtle spiculations remain sharp.

The researchers employ the simultaneous algebraic reconstruction technique as the base framework. This iterative process integrates the new filtering method at each step to update the final image volume.

The team measured the contrast-to-noise ratio and the full width at half maximum of line profiles. These metrics quantify the clarity of calcifications and the sharpness of mass boundaries across different reconstruction methods.

The authors claim that their method provides superior image quality compared to the total p-variation approach. They propose that this technique effectively preserves mass margins while simultaneously increasing the visibility of microcalcifications.