Background:
The Wellness-Fitness Initiative submaximal treadmill exercise test (WFI-TM) is recommended by the US National Fire Protection Agency to assess aerobic capacity (VO2 max) in firefighters. However, predicting VO2 max from submaximal tests can result in errors leading to erroneous conclusions about fitness.
Aims:
To investigate the level of agreement between VO2 max predicted from the WFI-TM against its direct measurement using exhaled gas analysis.
Methods:
The WFI-TM was performed to volitional fatigue. Differences between estimated VO2 max (derived from the WFI-TM equation) and direct measurement (exhaled gas analysis) were compared by paired t-test and agreement was determined using Pearson Product-Moment correlation and Bland-Altman analysis. Statistical significance was set at P < 0.05.
Results:
Fifty-nine men performed the WFI-TM. Mean (standard deviation) values for estimated and measured VO2 max were 44.6 (3.4) and 43.6 (7.9) ml/kg/min, respectively (P < 0.01). The mean bias by which WFI-TM overestimated VO2 max was 0.9ml/kg/min with a 95% prediction interval of ±13.1. Prediction errors for 22% of subjects were within ±5%; 36% had errors greater than or equal to ±15% and 7% had greater than ±30% errors. The correlation between predicted and measured VO2 max was r = 0.55 (standard error of the estimate = 2.8ml/kg/min).
Conclusions:
WFI-TM predicts VO2 max with 11% error. There is a tendency to overestimate aerobic capacity in less fit individuals and to underestimate it in more fit individuals leading to a clustering of values around 42ml/kg/min, a criterion used by some fire departments to assess fitness for duty.
More Related Videos
09:24A Rapidly Incremented Tethered-Swimming Maximal Protocol for Cardiorespiratory Assessment of Swimmers
Published on: January 28, 2020
07:09Assessment of Pulmonary Capillary Blood Volume, Membrane Diffusing Capacity, and Intrapulmonary Arteriovenous Anastomoses During Exercise
Published on: February 20, 2017
Related Concept Videos
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be...
Exercise and Cardiovascular Response
Light to moderate physical activity initiates a series of interconnected responses in the body. The heart rate modestly increases in anticipation of the workout, followed by widespread vasodilation as oxygen consumption by skeletal muscles increases. This results in decreased peripheral resistance, increased capillary blood flow, and accelerated...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...