Related Experiment Video
Updated: Apr 18, 2026

Troubleshooting FoCUS Image Acquisition: Patient Positioning, Transducer Manipulation, and Image Optimization
Published on: March 3, 2023
Screening for rheumatic heart disease: evaluation of a focused cardiac ultrasound approach
Mariana Mirabel1, Raoul Bacquelin2, Muriel Tafflet2
1From the Paris Cardiovascular Research Center, INSERM U970, Paris, France (M.M., R.B., M.T., K.N., X.J., E.M.); Université Paris Descartes, Sorbonne Paris Cité, Paris, France (M.M., A.A.H., X.J., E.M.); Cardiology Department, European Georges Pompidou Hospital, Paris, France (M.M., A.A.H., X.J., E.M.); Cardiology and Development, Paris, France (M.M., X.J., E.M.); Agence Sanitaire et Sociale de Nouvelle Calédonie, Nouméa, New Caledonia (C.R., B.H., P.C., J.-M.M., B.R.); Département de l'Action Sanitaire de Sociale des Iles Loyaté, Wé, Lifou, New Caledonia (I.d.F.); Cedars-Sinai Medical Center, Heart Institute, Los Angeles, CA (K.N.); and Centre Hospitalier Territorial de Nouvelle Calédonie, Nouméa, New Caledonia (B.N.). mariana.mirabel@inserm.fr.
Background:
Rheumatic heart disease (RHD) remains a major public health problem worldwide. Although early diagnosis by echocardiography may potentially play a key role in developing active surveillance, systematic evaluation of simple approaches in resource poor settings are needed.
Methods And Results:
We prospectively compared focused cardiac ultrasound (FCU) to a reference approach for RHD screening in a school children population. FCU included (1) the use of a pocket-sized echocardiography machine, (2) nonexpert staff (2 nurses with specific training), and (3) a simplified set of echocardiographic criteria. The reference approach used standardized echocardiographic examination, reviewed by an expert cardiologist, according to 2012 World Heart Federation criteria. Among the 6 different echocardiographic criteria, first tested in a preliminary phase, mitral regurgitation jet length≥2 cm or any aortic regurgitation was considered best suited to be FCU criteria. Of the 1217 subjects enrolled (mean, 9.6±1 years; 49.6% male), 49 (4%) were diagnosed with RHD by the reference approach. The sensitivity of FCU for the detection of RHD was 83.7% (95% confidence interval, 73.3-94.0) for nurse A and 77.6% (95% confidence interval, 65.9-89.2) for nurse B. FCU yielded a specificity of 90.9% (95% confidence interval, 89.3-92.6) and 92.0% (95% confidence interval, 90.4-93.5) according to users. Percentage of agreement among nurses was 91.4%.
Conclusions:
FCU by nonexperts using pocket devices seems feasible and yields acceptable sensitivity and specificity for RHD detection when compared with the state-of-the-art approach, thereby opening new perspectives for mass screening for RHD in low-resource settings.
Related Concept Videos
Rheumatic Heart Disease II: Clinical Manifestations and Diagnostic Studies
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Dysrhythmias V: Evaluating Dysrhythmias
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Rheumatic Heart Disease IV: Nursing Management
Rheumatic Heart Disease III: Medical Management