Related Experiment Video
Updated: Apr 18, 2026

Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
Assessing the challenges of a pulse wave velocity based blood pressure measurement in surgical patients
Abstract:
Development of a continuous noninvasive blood pressure (cNIBP) monitor that is unobtrusive to patients is an attractive alternative to the cuff based measurements performed on medical-surgical floors in the hospital. Pulse wave velocity (PWV) provides a means to continuously monitor blood pressure in these patients. However, a PWV based cNIBP monitor faces a number of challenges in order to accurately measure blood pressure. In our study, we investigated some of the challenges faced by a body-worn cNIBP monitor (i.e. ViSi Mobile) on data collected on patients undergoing surgery. Results indicated that 1) pulse arrival time (PAT) values from ViSi Mobile were well correlated with PAT values obtained from an invasive reference; 2) the reciprocal of the PAT measurements were linearly correlated with blood pressure but the calibration curve was altered by administration of certain vasoactive substances; and 3) there are deterministic correlations between systolic pressure, diastolic pressure and the corresponding mean arterial pressure over a wide range of blood pressure values.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(two-step method)