Feasibility of pulse presence and pulse strength assessment during head-up tilt table testing using an accelerometer
Abstract:
Neurally mediated syncope (NMS) is a disorder of the autonomic regulation of postural tone, which is characterized by hypotension and/or bradycardia, resulting in cerebral hypo-perfusion and finally in a sudden loss of consciousness. Prediction of an impending NMS requires detection of pulse presence to derive heart rate (HR) as well as to assess the pulse strength (PS) related to systolic blood pressure (SBP) preferably from a single body location only. This paper analyses the basic feasibility of using a single accelerometer positioned above the common carotid artery to assess pulse strength and pulse rate towards NMS prediction. A physical model has been investigated to gain insights into expected signal morphologies and potential feature candidates vs. hemodynamic parameters such as SBP, pulse pressure (PP) and PR relevant for NMS detection. Model results are compared with first measurements obtained in a head-up tilt table test (HUTT) from a patient during impending syncope. We show that an accelerometer positioned at the carotid artery is a potential approach offering a valuable tool in syncope management.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse Assessment Sites
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Pulse
The pulse serves as a clinical...
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation