Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Extraction: Partition and Distribution Coefficients01:14

Extraction: Partition and Distribution Coefficients

5.6K
The distribution law or Nernst's distribution law is the law that governs the distribution of a solute between two immiscible solvents. This law, also known as the partition law, states that if a solute is added to the mixture of two immiscible solvents at a constant temperature, the solute is distributed between the two solvents in such a way that the ratio of solute concentrations in the solvents remains constant at equilibrium.
For extracting a solute from an aqueous phase into an...
5.6K
Computed Tomography01:10

Computed Tomography

9.7K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
9.7K
¹H NMR Signal Multiplicity: Splitting Patterns01:13

¹H NMR Signal Multiplicity: Splitting Patterns

8.6K
When protons A and X are coupled, their nuclear spin energy levels are slightly modified. This is because the energy required to excite proton A to a spin state parallel to proton X is slightly different from the energy required for it to become anti-parallel to spin X. Consequently, there are two possible excitation frequencies for A (A1 and A2), depending on the spin state of X, and vice versa. The mutual nature of coupling implies that the difference between frequencies A1 and A2, indicated...
8.6K
Radiological Investigation II: MRI and Ventilation Perfusion Scan01:30

Radiological Investigation II: MRI and Ventilation Perfusion Scan

952
Description
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
952
Interpreting ¹H NMR Signal Splitting: The (n + 1) Rule01:10

Interpreting ¹H NMR Signal Splitting: The (n + 1) Rule

3.2K
In the AX proton spin system, proton A can sense the two spin states of a coupled proton X, resulting in a doublet NMR signal with two peaks of equal (1:1) intensity. When proton A is coupled to two equivalent protons (AX2 spin system), the spin states of each X can be aligned with or against the external field, creating three possible scenarios. This results in a 1:2:1  triplet signal, where the central peak corresponds to the chemical shift of A and is twice as large or intense as the...
3.2K
Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

10.5K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
10.5K

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Relaxation Time Mapping of Early-Stage Osteonecrosis of the Femoral Head: An In Vivo Piglet Model Study.

Journal of orthopaedic research : official publication of the Orthopaedic Research Society·2026
Same author

Incorporating Dental Anatomy Into MRI-Based Vocal Tract Models Using Zero Echo Time Imaging.

Journal of voice : official journal of the Voice Foundation·2026
Same author

MAP Image Recovery with Guarantees using Locally Convex Multi-Scale Energy (LC-MUSE) Model.

Proceedings of the ... IEEE International Conference on Acoustics, Speech, and Signal Processing. ICASSP (Conference)·2026
Same author

MEMORY-EFFICIENT DEEP END-TO-END POSTERIOR NETWORK (DEEPEN) FOR INVERSE PROBLEMS.

Proceedings. IEEE International Symposium on Biomedical Imaging·2025
Same author

ACCELERATING QUANTITATIVE MRI USING SUBSPACE MULTISCALE ENERGY MODEL (SS-MUSE).

Proceedings. IEEE International Symposium on Biomedical Imaging·2025
Same author

FAST MULTI-CONTRAST MRI USING JOINT MULTISCALE ENERGY MODEL.

Proceedings. IEEE International Symposium on Biomedical Imaging·2025
Same journal

Analysis of End-Tidal CO2 Variability During Plateau Waves Episodes: An Information Theoretic Approach<sup></sup>.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

AI and Tomosynthesis for Breast Cancer Molecular Subtyping: A step toward precision medicine<sup></sup>.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

Towards Sustainable Protein Recovery from Biological Waste: Assessing Polyethersulfone-based Microfiltration.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

Analysis of the cardiovascular response to standardized polymicrobial peritonitis experimental model.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

Automated Wrist Ultrasound Image Bone Enhancement and Segmentation Using Deep Learning.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
Same journal

A Deep Learning approach for Depressive Symptoms assessment in Parkinson's disease patients using facial videos.

Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference·2025
See all related articles

Related Experiment Video

Updated: Apr 18, 2026

Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging
10:44

Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging

Published on: June 21, 2024

1.4K

A variable splitting based algorithm for fast multi-coil blind compressed sensing MRI reconstruction.

Sampada Bhave, Sajan Goud Lingala, Mathews Jacob

    Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference
    |January 9, 2015
    PubMed
    Summary
    This summary is machine-generated.

    This study introduces a faster optimization algorithm for blind compressed sensing (BCS) in MRI. The new method significantly speeds up computations, making advanced BCS techniques more practical for medical imaging applications.

    More Related Videos

    Author Spotlight: Optimized Lung MRI Protocol with Computationally Efficient Reconstruction Methods
    05:07

    Author Spotlight: Optimized Lung MRI Protocol with Computationally Efficient Reconstruction Methods

    Published on: September 6, 2024

    908
    MRM Microcoil Performance Calibration and Usage Demonstrated on Medicago truncatula Roots at 22 T
    10:22

    MRM Microcoil Performance Calibration and Usage Demonstrated on Medicago truncatula Roots at 22 T

    Published on: January 16, 2021

    6.0K

    Related Experiment Videos

    Last Updated: Apr 18, 2026

    Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging
    10:44

    Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging

    Published on: June 21, 2024

    1.4K
    Author Spotlight: Optimized Lung MRI Protocol with Computationally Efficient Reconstruction Methods
    05:07

    Author Spotlight: Optimized Lung MRI Protocol with Computationally Efficient Reconstruction Methods

    Published on: September 6, 2024

    908
    MRM Microcoil Performance Calibration and Usage Demonstrated on Medicago truncatula Roots at 22 T
    10:22

    MRM Microcoil Performance Calibration and Usage Demonstrated on Medicago truncatula Roots at 22 T

    Published on: January 16, 2021

    6.0K

    Area of Science:

    • Medical Imaging
    • Signal Processing
    • Optimization Algorithms

    Background:

    • Blind compressed sensing (BCS) leverages data-driven dictionaries for improved performance over fixed-dictionary compressed sensing (CS).
    • A major limitation of BCS is its high computational complexity, hindering its application in Magnetic Resonance Imaging (MRI).

    Purpose of the Study:

    • To develop a novel optimization algorithm for BCS that enhances convergence speed.
    • To address the computational challenges associated with BCS in MRI applications.

    Main Methods:

    • Proposed a new optimization algorithm utilizing variable splitting strategies for BCS.
    • Decoupled sparse coefficient and dictionary update steps from the data fidelity term.
    • Achieved closed-form analytical solutions for subproblems, avoiding slower iterative methods.

    Main Results:

    • Demonstrated superior performance of BCS over conventional CS schemes on multi-coil parametric MRI data.
    • Achieved convergence speed-up factors exceeding 10-fold compared to previous BCS implementations.
    • Validated the practical utility of BCS through experimental results.

    Conclusions:

    • The novel BCS optimization algorithm significantly improves convergence speed.
    • This advancement makes BCS a more viable and efficient technique for MRI applications.
    • The proposed method offers a substantial computational advantage over existing BCS algorithms.