Related Experiment Video
Updated: Apr 18, 2026

E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
The effect of computer-aided detection markers on visual search and reader performance during concurrent reading of
Emma Helbren1, Thomas R Fanshawe, Peter Phillips
1Centre for Medical Imaging, University College London, London, UK.
Objective:
We aimed to identify the effect of computer-aided detection (CAD) on visual search and performance in CT Colonography (CTC) of inexperienced and experienced readers.
Methods:
Fifteen endoluminal CTC examinations were recorded, each with one polyp, and two videos were generated, one with and one without a CAD mark. Forty-two readers (17 experienced, 25 inexperienced) interpreted the videos during infrared visual search recording. CAD markers and polyps were treated as regions of interest in data processing. This multi-reader, multi-case study was analysed using multilevel modelling.
Results:
CAD drew readers' attention to polyps faster, accelerating identification times: median 'time to first pursuit' was 0.48 s (IQR 0.27 to 0.87 s) with CAD, versus 0.58 s (IQR 0.35 to 1.06 s) without. For inexperienced readers, CAD also held visual attention for longer. All visual search metrics used to assess visual gaze behaviour demonstrated statistically significant differences when "with" and "without" CAD were compared. A significant increase in the number of correct polyp identifications across all readers was seen with CAD (74 % without CAD, 87 % with CAD; p < 0.001).
Conclusions:
CAD significantly alters visual search and polyp identification in readers viewing three-dimensional endoluminal CTC. For polyp and CAD marker pursuit times, CAD generally exerted a larger effect on inexperienced readers.
Key Points:
• Visual gaze is attracted by computer-assisted detection (CAD) marks on polyps • Inexperienced readers' gaze is affected more by CAD than experienced readers. • CAD marks could mean that the unannotated endoluminal surface is relatively neglected. • Correct polyp identification is increased significantly by CAD.
More Related Videos
12:32Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
03:43Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
Related Concept Videos
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies III: Computed Tomography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Radiological Investigation I: X-ray and CT