Objectives:
To evaluate the accuracy of MRI of the breast (DCE-MRI) in a stand-alone setting with extended indications.
Materials And Methods:
According to the inclusion criteria, breast specialists were invited to refer patients to our institution for DCE-MRI. Depending on the MR findings, patients received either a follow-up or biopsy. Between 04/2006 and 12/2011 a consecutive total of 1,488 women were prospectively examined.
Results:
Of 1,488 included patients, 393 patients were lost to follow-up, 1,095 patients were evaluated. 124 patients were diagnosed with malignancy by DCE-MRI (76 TP, 48 FP, 971 TN, 0 FN cases). Positive cases were confirmed by histology, negative cases by MR follow-ups or patient questionnaires over the next 5 years in 1,737 cases (sensitivity 100 %; specificity 95.2 %; PPV 61.3 %; NPV 100 %; accuracy 95.5 %). For invasive cancers only (DCIS excluded), the results were 63 TP; 27 FP; 971 TP and 0 FN (sensitivity 100 %; specificity 97.2 %; PPV 70 %; NPV 100 %; accuracy 97.5 %).
Conclusion:
The DCE-MRI indications tested imply that negative results in DCE-MRI reliably exclude cancer. The results were achieved in a stand-alone setting (single modality diagnosis). However, these results are strongly dependent on reader experience and adequate technical standards as prerequisites for optimal diagnoses.
Key Points:
• DCE-MRI of the breast has a high accuracy in finding breast cancer. • The set of indications for DCE-MRI of the breast is still very limited. • DCE-MRI can achieve a high accuracy in a 'screening-like' setting. • Accuracy of breast DCE-MRI is strongly dependent on technique and reader experience. • A negative DCE-MRI effectively excludes cancer.
Related Concept Videos
Magnetic Resonance Imaging
Imaging Studies for Cardiovascular System IV: CMRI
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies IV: Magnetic Resonance Imaging