Related Experiment Video
Updated: Apr 18, 2026

In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint
Published on: March 7, 2014
Effect of the parafunctional occlusal loading and crown height on stress distribution
Leonardo Bueno Torcato1, Eduardo Piza Pellizzer1, Fellippo Ramos Verri1
1Department of Dental Materials and Prosthodontics, Araçatuba Dental School, UNESP - Univ Estadual Paulista, Araçatuba, SP, Brazil.
Abstract:
The aim of this study was to assess, by the three-dimensional finite element method, the influence of crown-to-implant ratio and parafunctional occlusal loading on stress distribution in single external hexagon implant-supported prosthesis. Computer-aided design software was used to confection three models. Each model was composed of a block bone and an external hexagon implant (5x10.0 mm) with screw-retained implant prostheses, varying the height crown: 10, 12.5 and 15 mm. Finite element analysis software was used to generate the finite element mesh and to establish the loading and boundary conditions. Normal (200 N axial and 100 N oblique load) and parafunctional forces (1,000 N axial and 500 N oblique load) were applied. The results were visualized by von Mises and maximum principal stress. In comparison with the normal occlusal force, the parafunctional occlusal force induced an increase in stress concentration and magnitude on implant (platform and first threads) and screw (neck). The cortical bone showed the highest tensile stress under parafunctional force (oblique load). The stress concentration increased as the crown height increased. It was concluded that: increasing the C/I increased stress concentration in both implant components and cortical bone; parafunctional loading increased between 4-5 times the value of stresses in bone tissue compared with functional loading; the type of loading variation factor is more influential than the crown-to-implant factor.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
07:32Author Spotlight: 3D Movement Assessment of Maxillary Posterior Teeth in Clear Aligner Treatment
Published on: February 23, 2024
Related Concept Videos
Components of Stress
Interestingly, the hidden cube faces also experience these stresses, equal and...
Stresses under Combined Loadings
The process begins by slicing the tube at critical points and analyzing the internal forces and stress components at these sections, focusing on the centroid. Normal stresses, generated by axial forces and bending moments, are either compressive or tensile and vary across the section from...
Stress: General Loading Conditions
The shearing force, possessing potential directionality within the plane of the section, is simplified into two component forces running parallel to the x and y axes....
Stress on an Oblique Plane
Stress Concentrations
Stress Concentrations
The stress...