Fractionating E-wave deceleration time into its stiffness and relaxation components distinguishes pseudonormal from
Sina Mossahebi1, Simeng Zhu1, Sándor J Kovács2
1From the Cardiovascular Biophysics Laboratory, Cardiovascular Division (S.M., S.Z., S.J.K), Department of Physics (S.M., S.Z., S.J.K.), and Department of Medicine, Cardiovascular Division (S.J.K), Washington University School of Medicine, St. Louis, MO.
Background:
Pseudonormal Doppler E-wave filling patterns indicate diastolic dysfunction but are indistinguishable from the normal filling pattern. For accurate classification, maneuvers to alter load or to additionally measure peak E' are required. E-wave deceleration time (DT) has been fractionated into its stiffness (DTs) and relaxation (DTr) components (DT=DTs+DTr) by analyzing E-waves via the parametrized diastolic filling formalism. The method has been validated with DTs and DTr correlating with simultaneous catheterization-derived stiffness (dP/dV) and relaxation (τ) with r=0.82 and r=0.94, respectively. We hypothesize that DT fractionation can (1) distinguish between unblinded (E' known) normal versus pseudonormal age-matched groups with normal left ventricular ejection fraction, and (2) distinguish between blinded (E' unknown) normal versus pseudonormal groups, based solely on E-wave analysis.
Methods And Results:
Data (763 E-waves) from 15 age-matched, pseudonormal (elevated E/E') and 15 normal subjects were analyzed. Conventional echocardiographic and parametrized diastolic filling stiffness (k) and relaxation (c) parameters and DTs and DTr were compared. Conventional diastolic function parameters did not differentiate between unblinded groups, whereas k, c (P<0.001) and DTs, DTr (P<0.001) did. Independent, blinded (E' not provided) analysis of 42 subjects (30 subjects from unblinded training set and 12 additional subjects from validation set, 581 E-waves) showed that R (=DTr/DT) had high sensitivity (0.90) and specificity (0.86) in differentiating pseudonormal from normal once E' revealed actual classification.
Conclusions:
arametrized diastolic filling-based E-wave analysis (k, c or DTs and DTr) can differentiate normal versus pseudonormal filling patterns without requiring knowledge of E'.
Related Concept Videos
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Atomic Nuclei: Types of Nuclear Relaxation
In spin–lattice or longitudinal relaxation, the excited spins exchange energy with the surrounding lattice as they return to the lower energy level. Among several mechanisms that contribute to spin–lattice relaxation, magnetic dipolar interactions are significant. Here, the excited nucleus transfers...
Correlation between ECG and Cardiac Cycle
A cardiac action potential originates in the SA node and spreads throughout the atria and the AV node in approximately 0.03 seconds. This results in the P wave in an ECG and triggers atrial contraction. The action potential is then briefly slowed at the AV node, allowing the atria to contract and fill the ventricles with blood before...
Double Resonance Techniques: Overview
Spin decoupling is usually achieved by...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...