Related Experiment Video
Updated: Apr 18, 2026

Asymmetrical Flow Field-Flow Fractionation for Sizing of Gold Nanoparticles in Suspension
Published on: September 11, 2020
Field-flow fractionation of nano- and microparticles in rotating coiled columns
Petr S Fedotov1, Mikhail S Ermolin1, Olesya N Katasonova2
1National University of Science and Technology "MISiS", 4 Leninsky Prospect, 119049 Moscow, Russia; Vernadsky Institute of Geochemistry and Analytical Chemistry, Russian Academy of Sciences, 19 Kosygin Street, 119991 Moscow, Russia.
Abstract:
Field-flow fractionation (FFF) is a very powerful and versatile set of liquid chromatography-like elution methods. However, conventional FFF separations occur in thin channels and the sample weight injected is usually less than 1 mg to avoid overloading. The fractionation in a rotating coiled column (RCC), which can be attributed to sedimentation FFF, enables the handling sample weight to be increased at least up to 1 g. An uneven distribution of particles in RCC was first observed by Y. Ito et al. in 1966. The work in this direction was continued by P.S. Fedotov et al. in 2000. Regularities of the behaviour of nano- and microparticles of different size and origin in RCCs with different design parameters were systematically studied taking as example silica particles, latex beads, quartz sand, clay minerals, and other samples. The basic principles of the new FFF method were established. The developed method was applied to the speciation analysis of polydisperse environmental samples, in particular, for the separation of soils into silt, clay and sand fractions. For the first time, nano- and submicron particles of street dust have been separated, weighted, characterized by electronic microscopy, and quantitatively analyzed by ICP-MS (after digestion). The elements that may be of anthropogenic origin (Zn, Cr, Ni, Cu, Cd, Sn, Pb) were found to concentrate mainly in <0.3 and 0.3-1 μm fractions. It has been shown that the concentrations of Cr, Ni, Zn in the finest fraction (<0.3 μm) of street dust can be one order of magnitude higher than the concentrations of elements in bulk sample. The fractionation in RCC was also used for the recovery of a nearly monodisperse fraction (4.5 μm) of a chromatographic sorbent based on polystyrene-divinylbenzene; impurities remaining from the synthesis and smaller particles (1-2 μm) being removed. Study on the fractionation of synthetic samples has demonstrated the applicability of the method to the preparative separation and purification of polydisperse materials.
Related Concept Videos
Centrifugation
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...