The effect of chlorhexidine on the push-out bond strength of calcium-enriched mixture cement
Fereshte Sobhnamayan1, Alireza Adl1, Nooshin Sadat Shojaee1
1Department of Endodontics, Dental School, Shiraz University of Medical Sciences, Shiraz, Iran;
Introduction:
The aim of this in vitro study was to evaluate the effect of 2% chlorhexidine (CHX) on the push-out bond strength (BS) of calcium-enriched mixture (CEM) cement.
Methods And Materials:
Root-dentin slices from 60 single-rooted human teeth with the lumen diameter of 1.3 mm were used. The samples were randomly divided into 4 groups (n=15), and their lumens were filled with CEM cement mixed with either its specific provided liquid (groups 1 and 3) or 2% CHX (groups 2 and 4). The specimens were incubated at 37(°)C for 3 days (groups 1 and 2) and 21 days (groups 3 and 4). The push-out BS were measured using a universal testing machine. The slices were examined under a light microscope at 40× magnification to determine the nature of bond failure. The data were analyzed using the two-way ANOVA. For subgroup analysis the student t-test was applied. The level of significance was set at 0.05.
Results:
After three days, there was no significant difference between groups 1 and 2 (P=0.892). In the 21-day specimens the BS in group 3 (CEM) was significantly greater than group 4 (CEM+CHX) (P=0.009). There was no significant difference in BS between 3 and 21-day samples in groups 2 and 4 (CEM+CHX) (P=0.44). However, the mean BS after 21 days was significantly greater compared to 3-day samples in groups 1 and 3 (P=0.015). The bond failure in all groups was predominantly of cohesive type.
Conclusion:
Mixing of CEM with 2% CHX had an adverse effect the bond strength of this cement.
Related Concept Videos
Bonding and Strength of Aggregate
Hydration of Cement
Transition Zone
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...
Testing Water Quality