Related Experiment Video
Updated: Apr 18, 2026

Non-invasive Optical Measurement of Cerebral Metabolism and Hemodynamics in Infants
Published on: March 14, 2013
Quality improvement measures in pulse-oximetry newborn heart screening: a time series analysis
Bethann Mangel Pflugeisen1, Paul J Amoroso1, Diane Zook2
1MultiCare Institute for Research and Innovation, Tacoma, Washington;
Background And Objectives:
The use of pulse-oximetry screening to detect critical congenital heart defects in newborns has gained national and international momentum in the past decade. Our hospital system began screening in 2008. Since then, our program has undergone leadership changes and multiple quality improvement interventions. The aims of this study are to evaluate the evolution of our pulse-oximetry program and to provide insights from lessons learned over the course of a long-standing program.
Methods:
We reviewed 6 years of screening data and evaluated trends of missed screens, false-positives, protocol violations, and parental decline of screening. We implemented 3 quality improvement interventions (change in protocol, redesign of an electronic medical record documentation system to autocalculate results, and transition from research to standard-of-care) and reviewed the impact of a rigorous quality assurance review process. We used linear regression and statistical process control charts to evaluate the data.
Results:
A total of 18,363 newborns were screened; we identified 5 critical cases. We observed a significant decrease in missed (P < .001) and false-positive (P = .03) screens over time but found no significant trend in the rate of percentage of protocol violations (P = .26) or decline of screening (P = .99). Each metric showed behavior attributable to at least 1 quality improvement intervention.
Conclusions:
We established a sustainable pulse-oximetry screening program in our community hospital system, and the screening has now become routine. The quality of our screening was influenced by choice of screening protocol, rigor of quality assurance reviews, and the process used to interpret screening results.
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Special considerations while measuring pulse
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:

