Selecting core-hole localization or delocalization in CS2 by photofragmentation dynamics

R Guillemin1, P Decleva2, M Stener2

  • 11] Sorbonne Universités, UPMC Univ Paris 06, UMR 7614, Laboratoire de Chimie Physique Matière et Rayonnement, F-75005 Paris, France [2] CNRS, UMR 7614, Laboratoire de Chimie Physique Matière et Rayonnement, F-75005 Paris, France.

Nature Communications
|January 22, 2015
PubMed

Related Concept Videos

IR Absorption Frequency: Delocalization01:04

IR Absorption Frequency: Delocalization

Electron delocalization refers to the distribution of electrons across multiple atoms within a molecule rather than being confined to a single atom or bond. This phenomenon is common in systems with conjugated bonds—structures where alternating single and double bonds allow π-electrons to move freely across the network. The movement of electrons stabilizes the molecule and can affect various chemical properties, including vibrational frequencies observed in IR spectroscopy.
In IR...
1.9K
π Electron Effects on Chemical Shift: Overview01:27

π Electron Effects on Chemical Shift: Overview

An applied magnetic field causes loosely bound π-electrons in organic molecules to circulate, producing a local or induced diamagnetic field over a large spatial volume. As the molecules tumble in solution, the field generated by π-electrons in spherical substituents results in a zero net field. However, the net field generated by π-electrons in non-spherical substituents is not zero. The effect of this induced field depends on the orientation of the molecule with respect to B0,...
1.9K
Mass Spectrometry: Cycloalkene Fragmentation00:54

Mass Spectrometry: Cycloalkene Fragmentation

The molecular ions of cycloalkenes undergo fragmentation via a retro-Diels–Alder reaction.
1.8K
Chemical Shift: Internal References and Solvent Effects01:17

Chemical Shift: Internal References and Solvent Effects

In an NMR sample, precise measurement of the absolute absorption frequencies of nuclei is difficult. A standard internal reference compound is added, and the frequency difference between the reference signal and sample signals is measured.
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
1.6K
Mass Spectrometry: Molecular Fragmentation Overview01:20

Mass Spectrometry: Molecular Fragmentation Overview

The ionization of a molecule into a molecular ion inside the mass spectrometer causes instability in the molecule's structure due to the loss of an electron. This eventually leads to the fragmentation or breaking of some bonds in the molecule. The fragmentation occurs predominantly at specific bonds to yield relatively stable fragments.
One type of fragmentation pattern is the cleavage of a single bond in the molecular ion. The cleavage leads to a radical and a cation. The cleavage can occur at...
6.8K
Protein Dynamics in Living Cells01:19

Protein Dynamics in Living Cells

Different fluorescence-based techniques are used to study the protein dynamics in living cells. These techniques include FRAP, FRET, and PET.
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
2.9K