Related Experiment Video
Updated: Apr 18, 2026

Microfluidic Platform with Multiplexed Electronic Detection for Spatial Tracking of Particles
Published on: March 13, 2017
An Optimal Pulse System Design by Multichannel Sensors Fusion
Abstract:
Pulse diagnosis, recognized as an important branch of traditional Chinese medicine (TCM), has a long history for health diagnosis. Certain features in the pulse are known to be related with the physiological status, which have been identified as biomarkers. In recent years, an electronic equipment is designed to obtain the valuable information inside pulse. Single-point pulse acquisition platform has the benefit of low cost and flexibility, but is time consuming in operation and not standardized in pulse location. The pulse system with a single-type sensor is easy to implement, but is limited in extracting sufficient pulse information. This paper proposes a novel system with optimal design that is special for pulse diagnosis. We combine a pressure sensor with a photoelectric sensor array to make a multichannel sensor fusion structure. Then, the optimal pulse signal processing methods and sensor fusion strategy are introduced for the feature extraction. Finally, the developed optimal pulse system and methods are tested on pulse database acquired from the healthy subjects and the patients known to be afflicted with diabetes. The experimental results indicate that the classification accuracy is increased significantly under the optimal design and also demonstrate that the developed pulse system with multichannel sensors fusion is more effective than the previous pulse acquisition platforms.
Related Concept Videos
Special considerations while measuring pulse
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Regulation of Pulse
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse Assessment Sites